Alarm 4 Faulty turbines
This delayed 7.5 amp fuse protects the motors; if it is stopped 20 seconds after starting the motor, the alarm shows an error. The
convection heating is cut off. The steam mode can be used.
Alarm 5 Heating elimination (only electrical)
If the equipment is connected to an energy management system and such system cuts off the equipment, the alarm shows an
error. The heating is stopped in all modes.
Alarm 6 (Electrical) counter overheating
A thermal probe near the static contactors checks the temperature of the radiator. If the temperature exceeds 65°C, the heating
is stopped.
Check the water tap to see if it is open.
Alarm 7 Faulty convection burner
This alarm is managed by the ignition distributor body. Check the gas supply and the polarity of the power plug.
In case of faults or alarms, contact the technical assistance service.