BLAST CHILLERS AND FREEZERS
INSTALLATION MANUAL n° 6CE648070NI
–0712
Page 9
4.3.3 PARAMETRES
Di
s
pl
ay
Cond
iti
on
Description
Mi
n
Max
F
ac
tory
ad
jus
t
Di
m.
Notes
P01
Temperature scale
1
2
1
1=°C, 2=°F
P02
Ambient probe calibration
-10
10
0
°K
P03
Skewer probe activation
0
1
1
0=NO, 1=YES
P04
T2=1
Skewer probe calibration
-10
10
0
°K
P05
Action digital entry 1
0
1
0
0=NON, 1=DOOR
P06
DI1 = 1
Polarity Digital Entry 1
0
1
0
0=NO, 1=NF
P07
Action Digital Entry 2
0
2
0
0=NON, 1=DIG INP, 2=EVP
P08
DI2 = 1
Polarity Digital Entry 2
0
1
0
0=NO, 1=NF
P09
Display Digital Entry 2
0
1
0
0=CD, 1=HP
P10
DI2 = 2
Evaporator probe calibration
-10
10
0
°K
P11
Presence of bar graph
0
1
1
0 : No, 1 : Yes
P12
Presence of light key
0
2
1
0 : No, 1: light key, 2:progression
cycle
P13
Type of buzzing sound
0
2
0
0: Frequency 1 (0.5s ON, 0.5s OFF)
1: Frequency 2 (0.35s ON, 0.35s OFF)
2: Frequency 3 (0.25s ON, 0.25s OFF)
P14
Max duration of sound alarm
-1
99
1
min
-1 = buzzer never stops
P15
Alarm repeated afterwards
-1
99
5
min
-1 = no repeat
P16
Function Standby
0
1
1
0=NO, 1=YES
P17
Standby timer
1
60
10
min
P18
Anti-smell function
0
1
0
0=NO, 1=YES
P19
Anti-smell timer
1
120
60
min
interval between the start of two
functions
P20
Anti-smell duration
1
120
30
min
duration of function
P69
Max duration anti-smell function
-1
24
6
hrs
-1=la fonction dure sans limite
P21
Display slowdown
0
100
0
P22
Machine number
1
255
1
P23
Manual defrost activated
0
1
1
0=NO, 1=YES
P24
Interval between 2 defrosting operations
0
99
6
hrs
P25
DI2=2
Temperature at end of defrost
-50
100
10
°C
Evaporator probe
P26
Max. duration of defrost
1
99
30
min
P27
Type of defrost
0
2
0
0=OFF, 1=ELE, 2=GAS
P28
Drainage time
0
99
3
min
P29
Check display on defrosting
0
60
10
min
P30
Ventilators activated during defrost
0
1
1
0=NO, 1=YES
P31
DI2=2
Temper. at ventilator switching on after
defrosting
-50
100
-5
°C
Evporator probe
P32
Ventilators switched off after defrost
0
60
0
min
P33
Defrost at the beginning of cooling cycle
0
1
0
0=NO, 1=YES
P34
Defrost at the beginning of conservation
cycle
0
1
0
0=NO, 1=YES
P35
Defrost delayed at the beginning of
conservation cycle
0
99
10
min
P36
Compressor delayed after switching on
0
30
0
min
P37
Min. time between 2 start-ups of
compressor
0
30
1
min
P38
Minimum standby duration after
compressor is switched off
0
30
1
min
P39
Compressor on with failing probe T1
0
30
3
min
P40
Compressor stopped with failing probe T1
0
30
6
min
P41
Compressor stop delayed by door opening
0
30
1
min
P42
Choice of cycle by default
0
3
0
0 = refriger. + S.P., 1 = delayed
refrigeration
2 = fr S.P., 3 = delayed
freezing