background image

- 3 -

• 

The router may only be connected to de

vices, 

which meet the requirements of EN 60950.

• 

The router is for indoor use only.

• 

Never open the router chassis. Unauthorized 

opening and improper repair can pose a danger 

to the user. Unauthorized modifications are not 

covered by the manufacturer’s warranty.

1  Safety instructions

•  Only qualified specialist personnel may install, 

start  up,  and  operate  the  router.  The  national 

safety and accident prevention regulations must 

be observed.

• 

The device is built to the latest technological 

standards and recognized safety standards 

(see Declaration of Conformity).

• 

The device is only intended for operation in the 

control cabinet and with SELV according to IEC 

60950/EN 60950/VDE 0805. 

   

Opening up the device voids the warranty!
NOTE: Electrostatic Discharge!

  

Observe the necessary safety precautions when handling components that 

are vulnerable to electrostatic discharge (EN 61340-5-1 and IEC 61340-5-1)!

 

2  Maintenance

The mbNETFIX Industrial Firewalls are maintenance-free units.

If an mbNETFIX have damage or malfunction, the device must be 

immediately taken out of service and secured against unintentional operation.

HINWEIS

Regardless of the maintenance-free hardware, there is a need for action in terms of IT security.

 

• 

Keep the software / firmware up to date.

• 

Keep yourself informed about security updates of the product.

Informationen hierzu finden Sie unter 

www.mbconnectline.com

Summary of Contents for 5.100.200.02.00

Page 1: ...00 5 920 000 02 00 HW02 EN DE Download link for your free version of mbNETFIX Manager https goo gl g6FQDV PROG CNTLR E482663 Quick start up guide EN V 1 0 1 25 10 2019 THE FIREWALL FOR THE AUTOMATION...

Page 2: ...ctory settings on delivery 15 13 Load factory settings Factory Reset 15 14 Technical data 16 15 Technical support 16 This document is valid for the device mbNETFIX NFH100 Item No 5 100 200 02 00 in ha...

Page 3: ...e is only intended for operation in the control cabinet and with SELV according to IEC 60950 EN 60950 VDE 0805 Opening up the device voids the warranty NOTE Electrostatic Discharge Observe the necessa...

Page 4: ...ncerned by this The use of the used open source software is possible free of charge We do not demand usage fees or any comparable fees for the use of the open source software contained in our products...

Page 5: ...ware programs outside of our product The warranty and liability regula tions that are pro vided by the respective effective open source software license for the respective open source software as list...

Page 6: ...ttacks from the Internet Easy network segmentation with controlled routing and NAT Convenient learning mode makes creation of filter tables simple easy Integration into existing networks Bridge or Gat...

Page 7: ...x Quick start up quide Art No 5 920 000 02 00 Should any of these parts are missing or damaged please contact the following address MB connect line GmbH Fernwartungssysteme Winnettener Str 6 91550 Di...

Page 8: ...interface 1 x USB slave 2 0 mini 0V DC connection Power source connection 10 30 V DC FE Functional earth I O 1 Digital input 10 30 V DC Low 0 3 2 V DC High 8 30 V DC I O 2 Digital input 10 30V DC Low...

Page 9: ...s WAN LAN LAN WAN LED off The packet filter is INACTIVE in both directions WAN LAN LAN WAN LED flashing The packet filter is INACTIVE in at least one direction WAN LAN LAN WAN Usr User LED on The devi...

Page 10: ...active packet filter in both directions Security By Default The packet filter can be switched INACTIVE by means of activating input 1 High 8 30 V DC You should choose this preference on input 1 if any...

Page 11: ...gh To do this use the supplied Plug in bridge 3 Connect the device to a power supply DC 10 30 V Make sure the polarity is correct LAN 1 Rdy Stat Usr 10 30 VDC Rdy Stat Usr Reset LAN 1 10 30 VDC I O LA...

Page 12: ...VE LED Stat flashes the packet filter is inactive LED Usr on the device has not yet been configured WAN LAN 3 LAN 2 LAN 1 Pwr Rdy Stat Usr Prog 10 30 VDC Pwr Rdy Stat Usr Function Reset Prog WAN LAN 3...

Page 13: ...learning mode is active That is the WAN LAN and LAN WAN transitions are open All pending connection attempts connections are detected Input 1 is only evaluated until the mbNETFIX has been configured o...

Page 14: ...the packet filter and the learning mode are active That is the WAN LAN and LAN WAN transitions are blocked All pending connection attempts are detected Use gateway mode if your network is on the LAN a...

Page 15: ...g address https goo gl g6FQDV After the installation you can configure the mbNETFIX for the respective purpose using a wizard 12 Factory settings on delivery Default settings mbNETFIX IP address USB p...

Page 16: ...nformation etc see our website www mbconnectline com For support enquiries always give the serial number of your mbNETFIX E mail support mbconnectline com Tel EU 49 0 98 51 58 25 29 900 US 1 630 797 6...