11
Configuration of the mbNETFIX
The configuration of the firewall is made via the USB interface using the software
mbNETFIX Manager
(not included in delivery).
In addition to a convenient graphical user interface (GUI) and public-key authentication,
the „
mbNETFIX Manager
“ offers all the functions that an automation engineer knows from
his PLC programming environment (eg export, import, duplicate, online comparison, online
functions, etc.).
Download the configuration software „mbNETFIX Manager“
for free
under the following address:
https://goo.gl/g6FQDV
After the installation, you can configure the mbNETFIX for the respective purpose using
a wizard.
12 Factory settings on delivery
Default settings
mbNETFIX
:
IP address (USB port): 169.254.0.1
Subnet Mask:
255.255.0.0
User 1:
admin
User 2:
factoryreset
Password:
The device password is located on the back of the device
and applies to both
User 1
and
User 2
.
13 Load factory settings (Factory Reset)
•
Open a project in the mbNETFIX Manager with the
user
„
factoryreset
“.
•
Connect to the mbNETFIX („
Go online
“).
•
In the „
Device
“ menu select the menu item „
Factoryreset
“.
•
Close the project and log in again with the
user
„
admin
“.
The mbNETFIX will now be reset to its original factory settings and must be reconfigured.