Video Intercom Vandal-Resistant Door Station
·
User Manual
29
If the device No. is set to 0, the door station works as the main door station.
If the device No. is larger than 0, the door station works as the sub door station.
The device No. can range from 1 to 99.
At least one main door station should be configured for each villa or building.
You can customize up to 8 sub door stations for each main door station.
5.
Click
Save
to finish the door station No. settings.
Operation Time
Purpose:
You can set the maximum speaking duration between the door station and other video
intercom devices, and the maximum message duration of the door station on the
operation time settings interface.
Steps:
1.
Enter the operation time settings interface:
Configuration > Video Intercom >
Operation Time Settings.
Figure 7-14
Set the Operation Time
2.
Set the Max. message duration and the Max. speaking duration.
3.
Click
Save
to finish the operation time settings.
Note:
The maximum message time varies from 30s to 60s.
The maximum speaking duration varies from 90s to 120s.
Access Control Parameters
Purpose:
On the access control settings interface, you can set the door No., and the
door-unlocked duration.
If you set the door-unlocked duration, the door will be locked automatically beyond the
set duration once the door is open.
Steps:
1.
Enter the access control settings interface:
Configuration > Video Intercom > Access
Control.