background image

18

PRODUCT DATA SHEETS

Interior Water Filtration System

Model UKF8001AXX-750 Capacity 750 Gallons (2839 Liters)

This system has been tested according to NSF/ANSI 

Standards 42 and 53 

for the reduction of the substances listed below. The 

concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the 
permissible limit for water leaving the system, as specified in NSF/ANSI 

Standards 42 and 53.

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 
71.6°F (20°C to 22°C).

It is essential that operational, maintenance, and filter 
replacement requirements be carried out for the product to 
perform as advertised.

The disposable water filter should be replaced at least every 
6 months.

The filter monitor system measures the amount of water that 
passes through the filter and alerts you to replace the filter. 
When 90% of the filter’s rated life is used, the yellow (Order) 
light comes on. When 100% of the filter’s rated life is used, 
the red (Replace) light comes on, and it is recommended that 
you replace the filter. For models without filter status lights, 
replace the filter every 6 months. Use replacement filter 
model UKF8001AXX-750. 2008 suggested retail price of 
$44.99 U.S.A./$49.95 Canada. Prices are subject to change 
without notice. 

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of 
unknown quality without adequate disinfection before or after 
the system. Systems certified for cyst reduction may be used 
on disinfected waters that may contain filterable cysts.

Refer to the “Water Filtration System” section for the 
Manufacturer’s name and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited 
warranty. 

Application Guidelines/Water Supply Parameters

System tested and certified by NSF International against NSF/ANSI 
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate 
Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead, 
Mercury, Atrazine, Benzene, p-Dichlorobenzene, Carbofuran, 
Toxaphene, Cysts, Turbidity, Asbestos and Lindane.

Substance Reduction
Aesthetic Effects

NSF Reduction 
Requirements

Average
Influent

Influent Challenge 
Concentration

Maximum
Effluent

Average
Effluent

Minimum%
Reduction

Average% 
Reduction

Chlorine Taste/Odor
Particulate Class I

*

50% reduction
85% reduction

1.88 mg/L
5,700,000 #/mL

2.0 mg/L ± 10%
At least 10,000 
particles/mL

0.06 mg/L
69,000 #/mL

**

0.05 mg/L
30,583 #/mL

96.84
98.94

>97.26
 99.52

Contaminant
Reduction

NSF Reduction 
Requirements

Average
Influent

Influent Challenge 
Concentration

Maximum
Effluent

Average
Effluent

Minimum%
Reduction

Average% 
Reduction

Lead: @ pH 6.5
Lead: @ pH 8.5

0.010 mg/L
0.010 mg/L

0.153 mg/L

0.150 mg/L

0.15 mg/L ± 10%
0.15 mg/L ± 10%

< 0.001mg/L
< 0.001mg/L

< 0.001mg/L
< 0.001mg/L

>99.29%
>99.29%

>99.35%
>99.33%

Mercury: @ pH 6.5
Mercury: @ pH 8.5

0.002 mg/L
0.002 mg/L

0.006 mg/L
0.006 mg/L

0.006 mg/L ± 10%
0.006 mg/L ± 10%

0.0005 mg/L
0.0015 mg/L

0.0003 mg/L
0.0008 mg/L

90.91
75.93

95.70
86.22

Benzene

0.005 mg/L

0.014 mg/L

0.015 mg/L ± 10%

0.0011 mg/L

0.0006 mg/L

92.14%

95.71%

p-Dichlorobenzene

0.075 mg/L

0.208 mg/L

0.225 mg/L ± 10%

< 0.0005 mg/L

< 0.0005 mg/L 99.74%

99.76%

Carbofuran

0.04 mg/L

0.081 mg/L

0.08 mg/L ± 10%

< 0.001mg/L

< 0.001mg/L

98.46%

98.74%

Toxaphene

0.003 mg/L

0.015 mg/L

0.015 ± 10%

< 0.001mg/L

< 0.001mg/L

91.67%

92.97%

Atrazine

0.003 mg/L

0.009mg/L

0.009 mg/L ± 10%

< 0.002 mg/L

< 0.002 mg/L 75.31%

76.99%

Asbestos

99%

155 MF/L

10

to 10

fibers/L

††

< 1 MF/L

< 1 MF/L

>99.99%

>99.99%

Live Cysts

Turbidity

>99.95%
0.5 NTU

166,500 #/L
10.7 NTU

50,000/L min. 
11 ± 1 NTU

< 1 #/L

0.49 NTU

< 1 #/L

0.31 NTU

>99.99
95.2

>99.99
97.09

Lindane

0.0002 mg/L

0.002 mg/L

0.002 ± 10%

< 0.0001mg/L

0.000 mg/L

96.50%

98.72%

Water Supply
Water Pressure
Water Temperature
Service Flow Rate

City or Well
35 - 120 psi (241 - 827 kPa)
33° - 100°F (1° - 38°C)
0.78 gpm (2.9 L/min.) @ 60 psi

*

**

††

Class I particle size: >0.5 to <1 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
Fibers greater than 10 um in length
Based on the use of Cryptosporidium parvum oocysts

® NSF is a registered trademark of NSF International.

Summary of Contents for W10208789A

Page 1: ...5 WATER FILTER CERTIFICATIONS 17 PRODUCT DATA SHEETS 18 WARRANTY 19 S CURIT DU R FRIG RATEUR 20 INSTRUCTIONS D INSTALLATION 21 UTILISATION DU R FRIG RATEUR 30 ENTRETIEN DU R FRIG RATEUR 35 D PANNAGE 3...

Page 2: ...owing WARNING SAVE THESE INSTRUCTIONS Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Disconnect power before servicing Replace all pa...

Page 3: ...or press the Freezer down arrow touch pad until a dash appears in both the Freezer and Refrigerator displays as shown Disconnect the refrigerator from the electrical source When you are finished recon...

Page 4: ...rmal sediment from collecting in the valve 4 Determine the length of copper tubing you need Measure from the connection on the rear of the refrigerator to the water pipe Add 7 ft 2 1 m to allow for cl...

Page 5: ...turn the refrigerator control OFF and remove food and adjustable door or utility bins from the doors Remove and Replace Refrigerator Door Handles Style 1 Standard Door Front Mount Handle To remove the...

Page 6: ...iring plug located on top of the top hinge by wedging a flat blade screwdriver or your fingernail between the two sections See Wiring Plug graphic NOTE The green ground wire remains attached to the hi...

Page 7: ...eplace Freezer Drawer IMPORTANT Two people may be required to remove and replace the freezer drawer All graphics are included later in this section after Final Steps Remove and Replace Drawer Handle M...

Page 8: ...C D A B C Bottom Hinge Door Swing Reversal optional 1 A Door Hinge Hole Plug 3 A A Cabinet Hinge Hole Plugs 1 2 A A Door Stop Screws B Door Stop 4 Side View Front View A B 1 1 1 A A Hex Head Hinge Scr...

Page 9: ...placement A 3 32 Setscrew A 3 32 Setscrew A A Metal Handle Metal Handle Plastic Handle Plastic Handle 1 1 2 2 Top Hinges A Hinge Cover Screw B Top Hinge Cover C 5 16 Hex Head Hinge Screws D Top Hinge...

Page 10: ...ard the cabinet and snap it into place 7 Replace the base grille Style 2 Freezer Drawer Models 1 Remove the base grille Grasp the grille firmly and pull it toward you 2 Raise or lower the cabinet Usin...

Page 11: ...al Controls For your convenience the temperature controls are preset at the factory When you first install your refrigerator make sure the controls are still set to the recommended setting as shown St...

Page 12: ...zer to the lowest temperature setting Press the Fast Ice touch pad again to return to the normal freezer set point NOTE When Fast Ice is on the and pads for the freezer control will not operate The Fa...

Page 13: ...OW and HIGH FRUIT LOW open for best storage of fruits and vegetables with skins VEGETABLES HIGH closed for best storage of fresh leafy vegetables Ice Maker on some models Turning the Ice Maker On Off...

Page 14: ...fer to the other You must thoroughly clean both sections to eliminate odors To avoid odor transfer and drying out of food wrap or cover foods tightly For stainless steel models stainless steel is corr...

Page 15: ...the back portion of the shield over the light assembly Freezer door models Top of the refrigerator compartment Insert the tabs on the shield into the liner holes on each side of the light assembly Sli...

Page 16: ...y closed Ice and Water The ice maker is not producing ice or not enough ice Refrigerator connected to a water supply and the supply shutoff valve turned on Connect refrigerator to water supply and tur...

Page 17: ...r or reinstall it correctly Refrigerator door closed completely Close the door firmly If it does not close completely see The doors will not close completely earlier in this section Recently removed t...

Page 18: ...SI Standard 53 for the reduction of Lead Mercury Atrazine Benzene p Dichlorobenzene Carbofuran Toxaphene Cysts Turbidity Asbestos and Lindane Substance Reduction Aesthetic Effects NSF Reduction Requir...

Page 19: ...10 The removal and reinstallation of your major appliance if it is installed in an inaccessible location or is not installed in accordance with Maytag s published installation instructions 11 Replacem...

Page 20: ...us de toujours lire tous les messages de s curit et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous signale les dangers potentiels de...

Page 21: ...r permettre les connexions des conduits d eau En cas d installation du r frig rateur pr s d un mur fixe laisser un espace minimum de 2 6 3 cm du c t de la charni re certains mod les n cessitent davant...

Page 22: ...bit d eau et cause une obstruction plus facilement Utiliser un tube en cuivre et v rifier s il y a des fuites Installer les tubes en cuivre seulement des endroits o la temp rature se maintient au des...

Page 23: ...du raccord sur le tube en cuivre comme on le voit sur l illustration Ins rer l extr mit du tube aussi loin que possible dans l ouverture de sortie du robinet Visser l crou de compression sur le racco...

Page 24: ...etirer les vis fixant la poign e la porte Voir l illustration 2 Montage frontal Pour r installer la poign e reprendre les directives de montage dans le sens inverse Poign e montage lat ral Pour retire...

Page 25: ...ir l illustration de la charni re sup rieure Soulever la porte de l axe de la charni re inf rieure REMARQUE ter le couvercle de l axe de la charni re inf rieure et le conserver pour utilisation ult ri...

Page 26: ...t r installer le tiroir du cong lateur Toutes les illustrations mentionn es dans les instructions suivantes sont incluses plus loin dans cette section apr s tapes finales D pose et r installation de l...

Page 27: ...du sens d ouverture de la porte facultatif 1 A Bouchon d obturation des trous de charni re de la porte 3 A A Bouchons d obturation des trous de charni re dans la caisse 1 2 A A Vis de but e de la port...

Page 28: ...3 32 A A Poign e en m tal Poign e en m tal Poign e en plastique Poign e en plastique 1 1 2 2 B A C D Fiche de branchement A Vis du couvercle de la charni re B Couvercle de la charni re sup rieure C V...

Page 29: ...urs tours et vous devriez tourner les deux vis de r glage des roulettes de fa on gale 5 Abaisser le pied de stabilisation de chaque c t en le tournant dans le sens horaire jusqu ce qu il touche bien l...

Page 30: ...mpartiment de r frig ration Les portes peuvent tre ouvertes et ferm es s par ment ou ensemble Il y a sur la porte de gauche du r frig rateur un joint charni re verticale Lors de l ouverture de la port...

Page 31: ...nvironnement est moins humide Ajustement des r glages de commande S il est n cessaire d ajuster la temp rature dans le compartiment de r frig ration ou de cong lation utiliser les r glages indiqu s da...

Page 32: ...au bout de 24 heures environ Temp Alarm alarme de d passement de temp rature La caract ristique Temp Alarm alarme de d passement de temp rature fournit des renseignements sur la temp rature en cas de...

Page 33: ...la pr f rence d sir e s affiche appuyer sur les touches ou du r frig rateur pour modifier le statut de la pr f rence 3 Enregistrer les pr f rences en appuyant sur la touche Door Alarm pendant 3 second...

Page 34: ...ement temps de changer le filtre eau Lorsque le t moin rouge Replace remplacer est allum un nouveau filtre eau doit tre install Il est recommand de remplacer le filtre eau au moins tous les 6 mois OU...

Page 35: ...nt afin d viter d ventuelles taches laiss es par l eau REMARQUE Lors du nettoyage de l acier inoxydable toujours frotter dans le sens du grain afin d viter des gratignures 4 Nettoyer r guli rement les...

Page 36: ...eur sont sur ON marche Voir Utilisation de la des commande s S agit il d une nouvelle installation Accorder 24 heures apr s l installation pour que le r frig rateur se refroidisse compl tement REMARQU...

Page 37: ...pas ou pas suffisamment de gla ons Le r frig rateur est il connect l alimentation en eau et le robinet d arr t d eau est il ouvert Brancher le r frig rateur l alimentation en eau et ouvrir le robinet...

Page 38: ...velle installation Rincer et remplir le syst me de distribution d eau Voir Distributeur d eau La pression de l eau est elle inf rieure 35 lb po 241 kPa La pression de l eau du domicile d termine l cou...

Page 39: ...ules classe I et en vertu de la norme NSF ANSI 53 r duction de plomb mercure atrazine benz ne p dichlorobenz ne carbofuran toxaph ne kystes turbidit amiante et lindane R d de substances Effets esth ti...

Page 40: ...s de rechange ou la main d uvre pour les gros appareils m nagers dont les num ros de mod le de s rie ont t enlev s modifi s ou ne peuvent pas tre facilement identifi s 12 La d coloration ou l oxydatio...

Reviews: