![Maytag Neptune FAV7500A Technical Information Download Page 12](http://html1.mh-extra.com/html/maytag/neptune-fav7500a/neptune-fav7500a_technical-information_1750587012.webp)
Component Testing Information
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless
testing requires power.
16023174
12
©2005 Maytag Services
Membrane Pad Continuity Checks
Unplug ribbon connector from display board. Touch probe of meter to the appropriate pin numbers listed in the chart.
Meter will show infinite unless the appropriate key is pressed.
Note:
When the Neptune TL is plugged in, the Machine Control Board will check the lid latch mechanism every 20
seconds. If found to be locked with no cycle running, the Control Board will send a signal to the switch to unlock the
lid.
Button Pin
Number
Home
5 & 3
Favorites
6 & 3
Back
5 & 4
Off
5 & 7
Start/Pause 6 & 7
Help
6 & 4
Stain Brain
5 & 8
Cycle Library 6 & 8
Pin # 2