4
Water and Electric
■
3/4" (19 mm) inlet valves for hot and cold water. Determine
water hardness levels. Hard or medium levels may require
a water softener.
■
A dedicated, GFCI-equipped circuit for each washer
(see “Electrical Requirements”).
Spacing
■
Washers require 2.4 ft (0.7 m) above the top for maintenance.
■
Washers require 0.79" (20 mm) between the sides for
maintenance and maximum door clearance.
■
Allow 20" (500 mm) behind washer and the wall for
maintenance.
Front View
2.4 ft
(0.7 m)
0.79"
(20 mm)
0.79"
(20 mm)
Side View
20"
(500 mm)
Anchoring Soft-Mount Models
■
If anchoring is necessary, secure the washer to the floor with
two anchoring bolts (not supplied).
■
Drill 2 holes for anchoring bolts, following the illustration to the
right.
■
If necessary, place the feet into a narrow U-shaped section,
so that the washer does not move during operation.
FRONT
A
C
D
J
I
F
E
G
H
B
– Position of feet
– Drilling points for anchoring bolts
Anchoring Dimensions (inches/mm) – Soft-Mount Models
Model
A
B
C
D
E
F
G
H
I
J
20 lb/9 kg
20.86/530 17.48/444
3.54/90
5.09/129.5
14.76/375
6.59/167.5
1.57/40
4.64/118
27.95/710
27.22/691.5
25 lb/11 kg
24.33/618 17.48/444 3.48/88.5 5.09/129.5
17.91/455
6.69/170
1.37/35
4.64/118
31.29/795
27.22/691.5
30 lb/14 kg
24.33/618 22.20/564 3.48/88.5 6.27/159.5
20.27/515
5.51/140
2.36/60
4.64/118
31.29/795
33.12/841.5
40 lb/18 kg
30.90/785 22.04/560 3.64/92.5 8.32/211.5
23.42/595
7.38/187.5
1.96/50
3.94/100
38.18/970
34.31/871.5
55 lb/24 kg
30.90/785 27.36/695 3.64/92.5 8.32/211.5
26.37/670
5.90/150
1.96/50
3.94/100
38.18/970
39.62/1006.5
65 lb/28 kg
30.90/785 30.31/770 3.64/92.5 8.32/211.5
26.37/670
5.90/150
1.96/50
3.94/100
38.18/970
42.60/1082