Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
16 16026293
©2005 Maytag Services
Control Component
Test
Procedure
Results
M1 Controlled
Sabbath Mode
Hold
CLOCK
pad for 5 seconds to
activate Sabbath mode.
Hold
CLOCK
pad for 5 seconds to
disable Sabbath mode.
Desired bake function must be initiated
before entering Sabbath mode.
"SAb" will flash for 5 seconds, then remain on until
timed-out or cancelled.
The status SAB is not fault code 5AB.
All pad inputs are disabled except for
CANCEL
and
CLOCK
pads.
This mode disables the normal 12 hour shutoff to
allow operation of the bake mode for a maximum of
72 hours.
The oven light is not disabled.
M1 Controlled
Child lock out
Press and hold
CANCEL
and
COOK
& HOLD
pads for 3 to 5 seconds until
beep sounds.
To reactivate the control, press and
hold
CANCEL
and
COOK & HOLD
pads
for 5 seconds.
This is a safety feature that can be used to prevent
children from accidentally programming the oven. It
disables the electronic oven control.
Child lockout features must be reset after a power
failure.
M1 Controlled
Diagnostic Code
Display
Press and hold
(Up Arrow)
pad
w
ithin 60 seconds of powering up
the unit.
Cycle through the codes using the
(Up Arrow)
or
(Down Arrow)
pads.
The last 5 diagnostic codes will be stored in the non-
volatile memory.
See
"
Description of Error Codes
"
for explanation.
M1 (AGS1740BD*, MGS5752BD*) "Quick Test" Mode for Electronic Range
Control
Follow procedure below to use the quick test mode. Entries must be made within 32 seconds of each other or the
control will exit the quick test mode.
1.
Press and hold
CANCEL
and
BROIL
pads for 5 seconds.
2. Once the control has entered the "Quick Test" mode, release both pads.
3. Press each of the following pads indicated in the table below.
NOTE:
First time one of the following pads is pressed, it activates the response.
The second time the pad is pressed, it deactivates the response.
NOTE:
This mode can only be entered within the first 5 minutes of power up.
NOTE:
If the temperature sensor is greater than 400° F or if the temperature sensor reaches 400° F while
under test, the Quick Test mode will be disabled.
Display will indicate the following:
Key Operation
[Bake]
Bake
relay activated
[Broil]
Broil
relay activated
[Keep Warm]
DLB
relay activated
[Cook&Hold]
Last Diagnostic Code displayed
[Clean] Beep
sounds
[Delay] (M1)
EEPROM Version Number
displayed
[Timer]
Main Code Version Number
displayed
[Clock]
All
Segments
On
[Up Arrow]
Even Segments
On
[Down Arrow]
Odd Segments
On
[Cancel]
End Factory Test Mode
Summary of Contents for MGS5752BD
Page 33: ...2005 Maytag Services 16026293 A 1 Appendix A...
Page 36: ...A 4 16026293 2005 Maytag Services Installation Instructions...
Page 37: ...2005 Maytag Services 16026293 B 1 Appendix B...
Page 50: ...B 14 16026293 2005 Maytag Services Care Information...
Page 51: ...2005 Maytag Services 16026293 C 1 Appendix C...
Page 52: ...C 2 16026293 2005 Maytag Services LP Conversion Instructions...
Page 53: ...2005 Maytag Services 16026293 C 3 LP Conversion Instructions...
Page 54: ...C 4 16026293 2005 Maytag Services LP Conversion Instructions...
Page 55: ...2005 Maytag Services 16026293 C 5 LP Conversion Instructions...