22
Spring Unit
Models MFS80, MFS100, and MFS125:
Adjust the spring units if a suspension part is not horizontal
(without wash load and water) or after the spring unit has been
replaced.
To adjust the spring unit, turn the nuts (2) the same number
of turns simultaneously on the opposite guiding rods (3). The
adjustment is correct when the gap in all four corners of the
suspended part is the same (X = 2.16"/55 mm) between the
plate edge (4) of the suspended part and the top surface of
the frame (5).
1. Spring unit
2. Adjusting nuts
3. Guiding rods
4. Suspended part
5. Washer frame
6. Spring suspension eyes
Fuse Capacities
Earth Leakage Trips
IMPORTANT:
A qualified technician must perform an earth
leakage trip function test at least once every 3 months.
If the washer is equipped with an earth leakage trip in the inlet
circuit of the electric switchboard, it must be tested regularly. The
earth leakage trip is very sensitive and helps avoid electric shock
during washer operation.
To test:
Press the earth leakage trip test button while the trip is under
tension. If the trip is functioning, it will shut off.
4
X
5
1
6
2
3
2
6
Models MFS180, MFS230, and MFS275:
These models are to be adjusted by the manufacturer.
1. Spring unit
2. Suspended part
3. Guiding rods
4. Washer frame
6. Spring suspension eyes
1
4
2
6
3
6
Check Wire
Diagram for
Fuse Number
MFS55 Only
(208-500V)
Other Models
(<250 Volt)
Other Models
(250-500 Volt)
Fuse 1
1A/500V
2.5 Amp/250V
1A/500V
Fuse 2
1A/500V
2.5 Amp/250V
1A/500V
Fuse 3
1.6A/250V
1.6A/250V
1.6A/250V
Fuse 4
1A/250V
1A/250V
1A/250V