Service Specifications
June 2005
16026365
© 2005 Maytag Services
7
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Service Test – 201 Mullion Heater Override (if equipped)
•
Press the Refrigerator Up Keypad
or Refrigerator Down Keypad
to change Mullion Heater from
cycling on with compressor (Off position) to 100% operation (On Position).
Service Test – 202 Default Defrost Operation
•
Press the Refrigerator Up Keypad
or Refrigerator Down Keypad
to change Defrost Operation from
normal adaptive defrost (Off position) to minimum time between defrosts (On position).
Service Test – 203 Show Temperature Set points
•
Press the Refrigerator Up Keypad
or Refrigerator Down Keypad
to change from showing actual
temperature (Off position) showing temperature set points only (On position).
Service Test – 211 Fresh Food Temperature Adjustment
•
Press the Refrigerator Up Keypad
or Down Keypad
to change calibration of Fresh Food
Temperature plus or minus in 1°F increments up to
±
6°F.
NOTE:
Temperature will read in Fahrenheit regardless of what current temperature scale is being used.
Service Test – 212 Freezer Temperature Adjustment
•
Press the Refrigerator Up Keypad
or Down Keypad
to change calibration of Freezer Temperature
plus or minus 1°F in increments up to
±
6°F.
NOTE:
Temperature will read in Fahrenheit regardless of what current temperature scale is being used.
Service Test – 221 Reset Default Settings
•
Press the Refrigerator Up Keypad
and Down Keypad
to force to dEF (default factory settings).