Component Specifications

 

16026365   June 

2005 

 

 

© 2005 Maytag Services

 

2

 

!

WARNING

 

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before 
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires 
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. 

Component 

Specifications all parts 
115VAC/60HZ unless noted 

 

Compressor run capacitor 

Volt .....................................................
Capacitance ......................................  

220 VAC 
15 

µ

fd 

±

 10% 

Compressor BTUH .................................................

Watt ...................................................
Current Lock rotor ..............................
Current Full load ................................
Resistance Run windings...................
Resistance Start windings..................  

905 BTUH 
60 Hz / 153  watts 
19.0 amps

±

 15% 

1.26 amps

±

 15% 

3.33 ohms

±

 15% 

4.28 ohms

±

 15% 

Electric damper control 

Maximum closing time 
Temperature Rating 
RPM 

36 seconds 
20

°

F- 110

°

Thermistor Temperature 

77

°

F....................................................

36

°

F ...................................................

0

°

F......................................................  

Resistance 
10,000 ohms

±

 1.8% 

29,500 ohms

±

 1.0% 

86,300 ohms

±

 1.8% 

Condenser motor 

Rotation (facing end opposite shaft) 
RPM 
Watt....................................................
Current ...............................................  

Clockwise 
1120 RPM 
3.4  watts

±

15%@115VAC 

0.085 amps

±

 15%@115VAC 

Evaporator fan motor 

Rotation (facing end opposite shaft) 
RPM…………………………………… 
Watt……………………………………. 
Note: Fan blade must be fully seated 
on shaft to achieve proper airflow. 

Clockwise  
2940 RPM 
4.6 

±

15% watts@115 VAC 

Overload/Relay 

Ult. trip amps @ 158°F (70°C) ...........
  Close temperature ...........................
  Open temperature ............................
Short time trip (seconds)....................
Short time trip (amps @77°F (25°C) ..  

2.67  amps

±

 15% 

142°F ±9° 
284°F ±9° 
10 seconds 

±

11 amps 

±

2amps 

Thermostat (Defrost) 

Volt ....................................................
Watt ...................................................
Current ...............................................
Resistance across terminals: 
Above 42°F ±5°..................................
Below 12°F ±7° ..................................  

120/240 VAC 
495 watts 
5.8/2.9 amps 
56 K ohms 
Open 
Closed 

Evaporator heater 

Volt.....................................................  
Wattage .............................................  
Resistance .........................................  

115 VAC 
470 

±

5% watts @ 115VAC 

29 

±

5% ohms 

Control board 

Volt.....................................................  
  

120VAC, 60 HZ 
See Control board troubleshooting section 

Water Valve  

Watts..................................................  

Brown side 35w,Yellow side 20w 

Super Cool Fan 

Rotation (facing end opposite leads)  
RPM…………………………………… 
Watt…………………………………… 

Counterclockwise 
1530 

±

 250 

1.2 @ 12 VDC 

Light switch / Interlock 

Type……………………………………..
Volt………………………………………
Current………………………………….. 

SPDT NO/NC 
125/250 VAC 
8/4 amps 

 

Summary of Contents for MFD 2561HEB

Page 1: ...ed Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization No Load Perform...

Page 2: ...000 ohms 1 8 29 500 ohms 1 0 86 300 ohms 1 8 Condenser motor Rotation facing end opposite shaft RPM Watt Current Clockwise 1120 RPM 3 4 watts 15 115VAC 0 085 amps 15 115VAC Evaporator fan motor Rotat...

Page 3: ...or Alarm Max Cool Freezer Refrigerator Order Replace 000 NOTE If the Program CODE is correct the Programming Mode is exited by closing the Refrigerator door s 7 Press the Refrigerator Temperature UP K...

Page 4: ...The service test functions are performed using the refrigerator display and keypad Enter the Service Test Mode by performing the following sequence of events 1 Open the Fresh Food door and press and h...

Page 5: ...resh Food Temperature or OP for open thermistor or SH for shorted thermistor Service Test 142 Freezer Thermistor Will Show Freezer Temperature or OP for open thermistor or SH for shorted thermistor Se...

Page 6: ...of the Sports Fill ON or OFF Service Test 173 Ambient Light if equipped Display shows light sensor measurement Hi or Lo Night light will turn on light sensor measures Lo By changing the sensor s expos...

Page 7: ...frost Off position to minimum time between defrosts On position Service Test 203 Show Temperature Set points Press the Refrigerator Up Keypad or Refrigerator Down Keypad to change from showing actual...

Page 8: ...000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization To avoid risk of electrical shock that can cause dea...