Component Specifications
16026365 June
2005
© 2005 Maytag Services
2
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Component
Specifications all parts
115VAC/60HZ unless noted
Compressor run capacitor
Volt .....................................................
Capacitance ......................................
220 VAC
15
µ
fd
±
10%
Compressor BTUH .................................................
Watt ...................................................
Current Lock rotor ..............................
Current Full load ................................
Resistance Run windings...................
Resistance Start windings..................
905 BTUH
60 Hz / 153 watts
19.0 amps
±
15%
1.26 amps
±
15%
3.33 ohms
±
15%
4.28 ohms
±
15%
Electric damper control
Maximum closing time
Temperature Rating
RPM
36 seconds
20
°
F- 110
°
F
1
Thermistor Temperature
77
°
F....................................................
36
°
F ...................................................
0
°
F......................................................
Resistance
10,000 ohms
±
1.8%
29,500 ohms
±
1.0%
86,300 ohms
±
1.8%
Condenser motor
Rotation (facing end opposite shaft)
RPM
Watt....................................................
Current ...............................................
Clockwise
1120 RPM
3.4 watts
±
15%@115VAC
0.085 amps
±
15%@115VAC
Evaporator fan motor
Rotation (facing end opposite shaft)
RPM……………………………………
Watt…………………………………….
Note: Fan blade must be fully seated
on shaft to achieve proper airflow.
Clockwise
2940 RPM
4.6
±
15% watts@115 VAC
Overload/Relay
Ult. trip amps @ 158°F (70°C) ...........
Close temperature ...........................
Open temperature ............................
Short time trip (seconds)....................
Short time trip (amps @77°F (25°C) ..
2.67 amps
±
15%
142°F ±9°
284°F ±9°
10 seconds
±
5
11 amps
±
2amps
Thermostat (Defrost)
Volt ....................................................
Watt ...................................................
Current ...............................................
Resistance across terminals:
Above 42°F ±5°..................................
Below 12°F ±7° ..................................
120/240 VAC
495 watts
5.8/2.9 amps
56 K ohms
Open
Closed
Evaporator heater
Volt.....................................................
Wattage .............................................
Resistance .........................................
115 VAC
470
±
5% watts @ 115VAC
29
±
5% ohms
Control board
Volt.....................................................
120VAC, 60 HZ
See Control board troubleshooting section
Water Valve
Watts..................................................
Brown side 35w,Yellow side 20w
Super Cool Fan
Rotation (facing end opposite leads)
RPM……………………………………
Watt……………………………………
Counterclockwise
1530
±
250
1.2 @ 12 VDC
Light switch / Interlock
Type……………………………………..
Volt………………………………………
Current…………………………………..
SPDT NO/NC
125/250 VAC
8/4 amps