background image

Service Specifications

 

June 2005 

 

16026365 

© 2005 Maytag Services

 

5

!

WARNING

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before 
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires 
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. 

 

Service Test – 112 Freezer Fan  

 

Press the Refrigerator Up

 k

eypad

 

 

 

and Refrigerator Down 

k

eypad

 

 

 

to toggle Freezer Fan On and Off. 

NOTE: 

Display will show state OFF or DC voltage. 

Service Test – 121 Damper Operation  

 

Press the Refrigerator Up

 k

eypad

 

 

 

and Down

 k

eypad 

 

 

to toggle Damper (OP) open and (CL) closed. 

NOTE:

 If damper is opening or closing it will not allow you to toggle damper and beep. Display will show state –CL 

or –OP if Damper is in the process of closing or opening. 

Service Test – 131 (3) Door Bottom Freezer Mullion Heater (if equipped) 

 

Press the Refrigerator Up

 K

eypad

 

 

 

and Refrigerator Down

 K

eypad 

 

 

to toggle Mullion Heater Off and 

On. 

Service Test – 141 Fresh Food Thermistor  

 

Will Show Fresh Food Temperature or OP for open thermistor or SH for shorted thermistor. 

Service Test – 142 Freezer Thermistor  

 

Will Show Freezer Temperature or OP for open thermistor or SH for shorted thermistor. 

Service Test – 143 Machine Compartment Thermistor  

 

Will Show Machine Compartment Temperature or, OP open thermistor or SH shorted thermistor. 

Service Test – 151 Fresh Food Door State 

 

Will show state of Fresh Food Door. OP (open) CL (closed). 

NOTE: 

 By pushing fresh food door switch you can toggle state from OP (open) to CL (closed). 

Service Test – 152 Freezer Food Door State 

 

Will show state of Freezer Door. OP (open) CL (closed). 

NOTE: 

 By pushing freezer door switch you can toggle state from OP (open) to CL (closed). 

Service Test – 161 Cube Dispenser (if equipped) 

 

Display shows the state of the Cube Dispenser (ON or OFF). 

NOTE: 

 By pushing Actuator pad you can control state of cube dispenser without opening Ice Chute door. 

Service Test – 162 Crusher Dispenser (if equipped) 

 

Display shows the state of the Crusher Dispenser (ON or OFF). 

NOTE: 

 By pushing Actuator pad you can control state of Crusher dispenser without opening Ice Chute door. 

Service Test – 163 Water Dispenser (if equipped) 

 

Display shows the state of the Water Dispenser (ON or OFF). 

NOTE: 

 By pushing Actuator pad or Bottle fill you can control state of Water dispenser. 

Summary of Contents for MFD 2561HEB

Page 1: ...ed Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization No Load Perform...

Page 2: ...000 ohms 1 8 29 500 ohms 1 0 86 300 ohms 1 8 Condenser motor Rotation facing end opposite shaft RPM Watt Current Clockwise 1120 RPM 3 4 watts 15 115VAC 0 085 amps 15 115VAC Evaporator fan motor Rotat...

Page 3: ...or Alarm Max Cool Freezer Refrigerator Order Replace 000 NOTE If the Program CODE is correct the Programming Mode is exited by closing the Refrigerator door s 7 Press the Refrigerator Temperature UP K...

Page 4: ...The service test functions are performed using the refrigerator display and keypad Enter the Service Test Mode by performing the following sequence of events 1 Open the Fresh Food door and press and h...

Page 5: ...resh Food Temperature or OP for open thermistor or SH for shorted thermistor Service Test 142 Freezer Thermistor Will Show Freezer Temperature or OP for open thermistor or SH for shorted thermistor Se...

Page 6: ...of the Sports Fill ON or OFF Service Test 173 Ambient Light if equipped Display shows light sensor measurement Hi or Lo Night light will turn on light sensor measures Lo By changing the sensor s expos...

Page 7: ...frost Off position to minimum time between defrosts On position Service Test 203 Show Temperature Set points Press the Refrigerator Up Keypad or Refrigerator Down Keypad to change from showing actual...

Page 8: ...000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization To avoid risk of electrical shock that can cause dea...