background image

Bottom Mount Refrigerator

Technical Information

 

June 2005 

 

16026365 

© 2005 Maytag Services

 

1

MFD 2561HEB MFD 2561HEB0, MFD 2561HEQ MFD 2561HEQ0,  
MFD 2561HES MFD 2561HES0, MFD 2561HEW MFD 2561HEW0 

 
Due to a possibility of personal injury or property damage, always contact an authorized technician for  
service or repair of this refrigerator. 

CAUTION

!

All safety information must be followed as provided in Service Manual 16025629. 
 

!

WARNING

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power 
before servicing unless testing is required. Discharge capacitors through a 10,000 ohm resistor before 
handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper 
grounding and polarization. 

 

No-Load Performance, Controls in Normal Position 

 

 
 

 

Kw/24 hr 

±

0.4 

 
 

Percent Run Time 

±

10% 

 
 

Cycles/24 hr 

±

25% 

Refrigerator Center 

Compartment 

Average Food 

Temperature 

±

3

°

 

Freezer Compartment 

Average Food 

Temperature 

±

3

°

Ambient 

°

70

°

       90

°

       110

°

 70

°

        90

°

       110

°

 70

°

       90

°

       110

°

 70

°

        90

°

         110

°

 70

°

        90

°

        110

°

 

25 cu ft 

1.2       1.80        2.6 

32          51         75 

28          24           19 

38          38          38 

0            0            0 

 

Temperature Relationship Test Chart 

 

 

Evaporator 

Outlet 

±

3

°

 

Evaporator 

 Inlet 

±

3

°

 

Suction Line 

±

7

°

 

Average Total 

Wattage 

±

10% 

Suction 

Pressure 

±

2 PSIG 

 

Head Pressure

±

 5 PSIG 

Ambient 

°

F

 70

°

              90

°

 70

°

             90

°

 70

°

              90

°

 70

°

             90

°

 70

°

             90

°

 70

°

              90

°

 

25 cu ft 

-20                -17 

-20                -17 

85               105 

135               140 

0                  0 

83               135 

Schematic 

 

Summary of Contents for MFD 2561HEB

Page 1: ...ed Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization No Load Perform...

Page 2: ...000 ohms 1 8 29 500 ohms 1 0 86 300 ohms 1 8 Condenser motor Rotation facing end opposite shaft RPM Watt Current Clockwise 1120 RPM 3 4 watts 15 115VAC 0 085 amps 15 115VAC Evaporator fan motor Rotat...

Page 3: ...or Alarm Max Cool Freezer Refrigerator Order Replace 000 NOTE If the Program CODE is correct the Programming Mode is exited by closing the Refrigerator door s 7 Press the Refrigerator Temperature UP K...

Page 4: ...The service test functions are performed using the refrigerator display and keypad Enter the Service Test Mode by performing the following sequence of events 1 Open the Fresh Food door and press and h...

Page 5: ...resh Food Temperature or OP for open thermistor or SH for shorted thermistor Service Test 142 Freezer Thermistor Will Show Freezer Temperature or OP for open thermistor or SH for shorted thermistor Se...

Page 6: ...of the Sports Fill ON or OFF Service Test 173 Ambient Light if equipped Display shows light sensor measurement Hi or Lo Night light will turn on light sensor measures Lo By changing the sensor s expos...

Page 7: ...frost Off position to minimum time between defrosts On position Service Test 203 Show Temperature Set points Press the Refrigerator Up Keypad or Refrigerator Down Keypad to change from showing actual...

Page 8: ...000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization To avoid risk of electrical shock that can cause dea...

Reviews: