Product Dimensions

*Range can be raised approximately 1" (2.5 cm) by adjusting the 

leveling legs.

Cabinet Dimensions

Cabinet opening dimensions shown are for 25" (64.0 cm) 
countertop depth, 24" (61.0 cm) base cabinet depth and
36" (91.4 cm) countertop height.

IMPORTANT: If installing a range hood or microwave hood 
combination above the range, follow the range hood or 
microwave hood combination installation instructions for 
dimensional clearances above the cooktop surface.

A freestanding range may be installed next to combustible walls 
with zero clearance.

*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal 

cabinet is covered by not less than 

¹⁄₄

" (0.64 cm) flame retardant 

millboard covered with not less than No. 28 MSG sheet steel, 
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 
0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance between the top of the 
cooking platform and the bottom of an uncovered wood or metal 
cabinet.

Electrical Requirements - U.S.A. Only

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.

Do not use an extension cord.

Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.

A copy of the above code standards can be obtained from: 
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269.

WARNING: Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. Check with a 
qualified electrician or service technician if you are in doubt as to 
whether the appliance is properly grounded. Do not modify the 
power supply cord plug. If it will not fit the outlet, have a proper 
outlet installed by a qualified electrician.

A. 27

¹⁷⁄₃₂

" (69.9 cm) max. depth with handle

B. 46

⁷⁄₈

" (119.1 cm) overall height (max.) with leveling legs 

screwed all the way in*

C. 36" (91.4 cm) cooktop height (max.) with leveling legs screwed 

all the way in*

D. 29

⁷⁄₈

" (75.9 cm) width

E. 25" (63.5 cm) depth

F. Model/serial rating plate (located on the left side frame behind 

storage drawer panel)

A

B

C

D

E

F

A. 13" (33.0 cm) max. upper cabinet depth
B. 30" (76.2 cm) min. opening width

C. For minimum clearance to top of cooktop, see NOTE*.
D. 30

¹⁄₈

" (76.5 cm) min. opening width

E. Outlet - 8" (20.3 cm) to 22" (55.9 cm) from either cabinet,

5

¹⁄₂

" (14.0 cm) max. from floor

F.

⁷⁄₈

" (2.2 cm) min. required between cutout and cabinet door or 

hinge.

A

B

D

F

E

C

Summary of Contents for MER7662WQ - Ceramic Range

Page 1: ... potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can ki...

Page 2: ...5 12 7 cm beyond the bottom of the cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The floor anti tip bracket must be installed To install the anti tip bracket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See Electrical Requirements section IMPORTANT To avoid damage to your cabinets check ...

Page 3: ...codes Do not use an extension cord Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 WARNING Improper connection of the equipment groundi...

Page 4: ...The ground must be revised so the green ground wire of the 4 wire power supply cord is connected to the cabinet See Electrical Connection Grounding through the neutral conductor is prohibited for new branch circuit installations 1996 NEC mobile homes and recreational vehicles or an area where local codes prohibit grounding through the neutral conductor When a 4 wire receptacle of NEMA Type 14 50R ...

Page 5: ...unt anti tip bracket to wood floor drill two 3 2 mm holes at the positions marked on the bracket template Remove template from floor To mount anti tip bracket to concrete or ceramic floor use a 4 8 mm masonry drill bit to drill 2 holes at the positions marked on the bracket template Remove template from floor Tap plastic anchors into holes with a hammer 6 Align anti tip bracket holes with holes in...

Page 6: ... remove cover from range 3 Add strain relief Style 1 Power supply cord strain relief Remove the knockout for the power supply cord Assemble a UL listed strain relief in the opening Tighten strain relief screw against the power supply cord WARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these instruct...

Page 7: ...ct the neutral center wire to the center terminal connector using one of the hex washer head screws Securely tighten screw for proper electrical connection 5 Connect the other 2 wires lines 1 and 2 to the outer aluminum terminal blocks 6 Securely tighten screws for proper electrical connection 7 Tighten strain relief screws 8 Replace terminal block cover A Removable retaining nut B Strain relief I...

Page 8: ...ehicles In an area where local codes prohibit grounding through the neutral 1 Remove the ground link screw from the range frame Save the ground link screw and cup washer Bend the ground link away from the range so that it does not contact the range 2 Connect the bare ground wire to the range using the ground link screw and cup washer The ground wire must be attached first and must not contact any ...

Page 9: ...flashlight and look underneath the bottom of the range Look for the anti tip bracket securely attached to floor Slide range back so rear range foot is under anti tip bracket LevelRange 1 Place rack in oven 2 Place level on rack and check levelness of range first side to side then front to back 3 If range is not level pull range forward until rear leveling leg is removed from the anti tip bracket O...

Page 10: ...ian MovingtheRange When moving range slide range onto cardboard or hardboard to avoid damaging the floor covering If removing the range is necessary for cleaning or maintenance For power supply cord connected ranges 1 Slide range forward 2 Unplug the power supply cord 3 Complete cleaning or maintenance 4 Plug in power supply cord 5 Check that anti tip bracket is installed Look for the anti tip bra...

Page 11: ...11 ANTI TIP BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall Left edge Top edge ...

Page 12: ...W10196158B 2008 All rights reserved 8 08 Printed in U S A ...