SECTION IX
REVERSING TIMER SPIN / DWELL ADJUSTMENTS
Timer models have an electric reversing timer in the electric service box, which is located in the upper left rear
area of the dryer.
Both the dwell (stop) time and tumbler spin time are adjustable by mode selection switches located on the
electronic timer (refer to the
illustration below
).
TIMING LEGEND
SPIN TIME
Adjustment Position Number
1
2
3
4
5
Time in Seconds
*
30
60
90
120
150
DWELL (STOP) TIME
Adjustment Position Number
1
2
3
4
5
Time in Seconds
*
5
6.3
7.6
8.9
10.2
* Values shown are +/- 1-second.