background image

Troubleshooting 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless  
testing requires power. 
 

16026116 

Rev. 

         March 

2005 

 

 

©2005 Maytag Services

 

4

opposite direction, the more recent code will be 
displayed.  
 
While a diagnostic code is displayed, if the 

Start/Pause

 

button in the center of the Rotary Cycle Selector is 
pressed and held, the machine will display the number of 
cycles ago the diagnostic code occurred. When the 

Start/Pause

 button is released, the diagnostic code is 

again displayed

 

Clearing Diagnostic Codes 

To clear the diagnostic code list press the 

Sensor Dry 

Level

 and 

Time

 keypads together for 3 seconds while 

viewing the list. The cycle count for each diagnostic code 
will be reset to 0, but not the machine cycle count. 
 

Diagnostic Codes

 

Code Description  Trigger 

Action 

Taken 

Dryer 
Thermistor 
Short Sensed 

The 
Thermistor 
resistance is 
very low. 

Check for:   

Clogged lint 
screen. 

Restricted vent 
system.

 

Check Thermistor 
resistance. 

Thermistor 
Open Sensed  

The 
Thermistor 
resistance is 
very high 

Check for:  

Low ambient 
temperature in 
room (Below            

-22

°

F/-30

°

C). 

Outside vent 
damper is stuck 
open in 
wintertime. 

Loose or open 
wire terminals. 

Check Thermistor 
resistance. 

Door Circuit 
Failure 

Invalid state 
for more 
than 256 
milliseconds

 

Check for: 

Loose or open 
wire terminals in 
Door Sense 
circuit. 

Possible motor 
transistor error 

If either 
motor 
transistor is 
seen open 
or shorted 
during 
startup 

Check for: 

Loose 
connections in 
motor circuit. 

Run System 
Check Mode and 
check the motor 
relay function. 

If relay functions, 
disregard the          
diagnostic code. 

If relay does not 
function, replace 
machine control 
board. 

Code Description  Trigger 

Action 

Taken 

Stuck Key 

A key is 
sensed to be 
pressed 
more than 
75 seconds, 
the key is 
assumed to 
be stuck.  

 Run membrane pad 
check and replace 
console 
w/membrane pad if 
necessary. 

10 

No Wet Clothes  

Sensor bar 
detects no 
wet clothes 
while a 
Sensor Dry 
Cycle 

Check for: 
- Running dryer with 
no wet clothes in 
sensor dry cycle 
 

 
 

Display Fault/Error Codes 

Disp Description 

 

Trigger 
 

Action Taken 
 

tS 

 

Dryer 
Thermistor 
Short Sensed 

 

The Thermistor 
resistance is very 
low.

 

Check for: 
- Clogged lint 

screen. 

- Restricted vent 
  system. 
- Check Thermistor 
   resistance. 
- Check for 
diagnostic code 1

 

do 

 

Door Open 

 

Running the dryer 
with door open

 

Check for: 
- Close the door, 

and run the dryer 

- Loose or open 

wire terminals in 
Door Sense 
circuit. 

- Check for 

diagnostic code 3

FE 

 

Power source 
frequency error 

 

Invalid power 
source frequency

 

Check for: 
- Not using regular 

power source 
frequency 

- Invalid power 

frequency sense 
circuit

 

dC 

 

Door Circuit 
Failure 

 

Invalid state for 
more than 256 
milliseconds

 

Check for: 
- Loose or open 

wire terminals in 
Door Sense 
circuit.  

- Check for 

diagnostic code 3

 

hE 

 

Heater Error 
 

Invalid heating 
temperature in 
running the dryer 

Check for: 
- Restricted vent 

system. 

- Check Thermistor 

resistance. 

 

 
 
 
 

Reviews: