background image

Troubleshooting 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless  
testing requires power. 

 

March 

2005 

          16026116 

Rev. 

©2005 Maytag Services 

 

3

Exit Service Mode 

Press the 

OFF 

key to exit Service Mode or repeat the 

Chime

 

and 

Temperature 

sequence. 

 

Diagnostic Tests 

The following table lists the various tests available while 
in the Service Mode. Before advancing to the next test, 
the current test running must be terminated. 
 
Press the following keys to access: 

Key Press 

Special 
Test/Function 

Wrinkle Prevent 

Displays “

d

” 

 
Then rotate the 

Cycle 

Selector Knob

 

 
 

Display list of 
diagnostic codes. 
 
To sequence thru 
the diagnostic and 
help codes. 

Temperature

 Key

 

 

Display software 
revision number 
 

Start/Pause 

Start or pause cycle 
running but remain 
in diagnostic mode. 
Display the number 
of cycles ago the 
diagnostic code 
occurred. 

 

System Check Mode 

While in Service Mode, pressing the  

Time 

and 

Wrinkle Prevent

 keys for 3 seconds, will put 

the dryer into the System Check mode and "

in

" will 

display. The following table lists the various functions 
based on the keys being pressed. 
 

System Check Mode Table

 

 

Key Pressed: 

Function Performed 

Start/Pause rotary 
selector dial 

Cycles the motor 
on/off.  

Rotate the Cycle Selector 
Knob to

 Delicates 

 

LED’s and 7 segment 
display flash. 

Rotate the Cycle Selector 
Knob to 

Sensor 

Dry 

 

View current cycle 
temperature in 
Celsius. 

Rotate the Cycle Selector 
Knob to 

Wrinkle Control

 

 

Segment display 
is “1” for sensor 
bar short, “0” for 
sensor bar open 

Key Pressed: 

Function Performed 

Rotate the Cycle Selector 
Knob to 

Time Dry

 

 

View current cycle 
temperature in 
Fahrenheit. 

 

LED/Switch Check 

While in

 

Service

 

Mode, pressing the

 Chime

 and 

Wrinkle 

Prevent 

keys for 3 seconds, will start a LED/Switch Test. 

To exit the test at any point, press the same keys again 
for 3 seconds or press the 

OFF

 key to exit Service 

Mode. 
 
Perform the check by pressing the keys which toggle the 
LED’s on and off. 
 
All switch pads must be pressed within 5 minutes for this 
test to pass. 

PA

 will be displayed for five (5) seconds 

once all switch pads have been pressed and this test is 
completed. Following 10 seconds of inactivity at any 
point, the test will exit without any display. The 

Power 

Off

 

switch pad must be pressed twice within thirty (30) 

seconds to cancel this test. 
 

Switch Action 

Wrinkle Prevent 

Press once 

Chime Press 

twice 

Adjust Time 

Press once 

Time 

Press four times 

Temperature 

Press three times 

Dryness Level 

Press four times 

Selector Knob 

Rotate 1 position 

Start Pause 

Press once 

Off Press 

once 

 

Diagnostic Codes 

The Diagnostic Codes are identified when the severity 
level of the abnormality detected is higher and service 
may be required. 
 
When a problem with the dryer is detected a Diagnostic 
Code is assigned, and can be displayed. The Control 
Board will not log multiple same codes per cycle; 
however, it will log as many Diagnostics as possible for 
the machine to continue running.

 

 

Access Diagnostic Codes by entering the Service Mode 
and pressing 

Wrinkle Prevent

.

 

d

 

will be displayed.

 

 

Rotate the Cycle Selector Knob in either direction to step 
through the list of codes one code at a time. Once an 
initial direction is selected by the user (either Clockwise 
or Counterclockwise), subsequent movements of the 
knob in the same direction will show older codes. If the 
user changes direction and turns the knob in the 

 

Reviews: