24
4. Grounding
Grounding (earth) connections
must be
provided and installed in accordance with state and local codes. In
the absence of the codes, grounding
must conform
to applicable requirements of the National Electrical
Code ANSI/NFPA NO.70 LATEST EDITION. The ground connection may be to a proven earth ground at
the location service panel.
NOTE
: A grounding connection (terminal lug) is provided in the dryer's electrical service/relay box at
the rear, upper left hand corner of the dryer.
For added personal safety, when possible, it is suggested that a separate ground wire (sized per local codes)
be connected from the ground connection of the dryer to a grounded cold water pipe.
DO NOT ground to
a gas or hot water pipe.
The grounded cold water pipe
must have
metal to metal connections all the way
to electrical ground. If there are any non-metallic interruptions, such as a meter, pump, plastic, rubber, or
other insulating connectors, they
must be
jumped out with no. 4 copper wire and securely clamped to bare
metal at both ends.
IMPORTANT
: For personal safety and proper operation, the dryer
must be
grounded. For proper
operation of the microprocessor (computer), an earth (zero) ground
is
required
.
NOTE
: Grounding via metallic electrical conduit (pipe)
is
not
recommended
.
Summary of Contents for MD-170