22
The burner needs to be removed for cleaning.
Call Maytag
Customer Service at 1-800-788-8899 for an authorized
servicer to remove and clean the burner and correct the
problem that required the burner to be cleaned.
Housekeeping
Vacuum around base of water heater for dust, dirt, and lint on a
regular basis.
AT LEAST ONCE EVER
AT LEAST ONCE EVER
AT LEAST ONCE EVER
AT LEAST ONCE EVER
AT LEAST ONCE EVERY SIX MONTHS
Y SIX MONTHS
Y SIX MONTHS
Y SIX MONTHS
Y SIX MONTHS A
A
A
A
A
VISUAL INSPECTION SHOULD BE MADE OF
VISUAL INSPECTION SHOULD BE MADE OF
VISUAL INSPECTION SHOULD BE MADE OF
VISUAL INSPECTION SHOULD BE MADE OF
VISUAL INSPECTION SHOULD BE MADE OF
THE
THE
THE
THE
THE AIR INT
AIR INT
AIR INT
AIR INT
AIR INTAKE SCREEN
AKE SCREEN
AKE SCREEN
AKE SCREEN
AKE SCREEN..... CLEAN IF LINT
CLEAN IF LINT
CLEAN IF LINT
CLEAN IF LINT
CLEAN IF LINT
A
A
A
A
ACCUMULA
CCUMULA
CCUMULA
CCUMULA
CCUMULATIONS
TIONS
TIONS
TIONS
TIONS ARE NO
ARE NO
ARE NO
ARE NO
ARE NOTICED
TICED
TICED
TICED
TICED.....
INSTALLED IN SUITABLE AREA: To insure sufficient ventilation
and combustion air supply, proper clearances from the water
heater must be maintained.
See Facts to Consider About the
Location
section. Combustible materials such as clothing,
cleaning materials, or flammable liquids, etc. must not be
placed against or adjacent to the water heater which can cause
a fire.
Anode Rod Inspection
The anode rod is used to protect the tank from corrosion. Most
hot water tanks are equipped with an anode rod. The
submerged rod sacrifices itself to protect the tank. Instead of
corroding the tank, water ions attack and eat away the anode
rod. This does not affect the water’s taste or color. The rod
must be maintained to keep the tank in operating condition.
Anode deterioration depends on water conductivity, not
necessarily water condition. A corroded or pitted anode rod
indicates high water conductivity and should be checked and/
or replaced more often than an anode rod that appears to be
intact. Replacement of a depleted anode rod can extend the
life of your water heater. Inspection should be conducted by a
qualified technician. At a minimum, the anode(s) should be
checked annually after the warranty period.
Temperature-Pressure Relief Valve Operation
The temperature-pressure relief valve must be manually
operated at least once a year.
When checking the temperature-pressure relief valve operation,
make sure that (1) no one is in front of or around the outlet of
the temperature-pressure relief valve discharge line, and (2)
that the water discharge will not cause any property damage,
as the water may be extremely hot, see Figure 25.
FIGURE 25.
If after manually operating the valve, it fails to completely reset
and continues to release water, immediately close the cold
water inlet to the water heater, follow the draining instructions,
and replace the temperature-pressure relief valve with a new
one.
If the temperature-pressure relief valve on the appliance weeps
or discharges periodically, this may be due to thermal
expansion. You may have a check valve installed in the water
line or a water meter with a check valve.
Consult Maytag
Customer Service at 1-800-788-8899 for further information.
Do not plug the temperature-pressure relief valve.
Draining
The water heater should be drained if being shut down during
freezing temperatures. Also periodic draining and cleaning of
sediment from the tank may be necessary.