5
TANK
RECOVERY
MINIMUM
DIMENSIONS
CAPACITY
TYPE
RATE GALS.
VENT PIPE
DIAMETER
IN INCHES (mm)
IN GALS
OF
BTU
PER HOUR
INCHES
INCHES
HEIGHT TOP OF
MODEL NUMBER
(LTRS)
GAS
RATE
@ 90°F RISE
( m m )
( m m )
DRAFT HOOD
HRN4930T
30 (114)
NATURAL
35,500
36.0
3” (76)
16” (406)
61” (1,549)
HRP4930T
30 (114)
PROPANE
37,000
41.0
3" (76) or 4" (102)
16" (406)
62" (1,575)
HRN4940S
40 (151)
NATURAL
40,000
41.0
3" (76) or 4" (102)
20" (508)
52" (1,321)
HRP4940S
40 (151)
PROPANE
37,000
41.0
3" (76) or 4" (102)
20" (508)
52" (1,321)
HRN4940T
40 (151)
NATURAL
40,000
41.0
3" (76) or 4" (102)
18" (457)
62 1/2" (1,588)
HRP4940T
40 (151)
PROPANE
37,000
41.0
3" (76) or 4" (102)
18" (457)
62 1/2" (1,588)
HRN4950S
50 (189)
NATURAL
40,000
41.0
3" (76) or 4" (102)
24” (645)
52 1/2” (1,333)
HRP4950S
50 (189)
PROPANE
35,500
37.0
3" (76) or 4" (102)
24” (645)
52 1/2” (1,333)
HRN4950T
50 (189)
NATURAL
40,000
41.0
3" (76) or 4" (102)
20” (508)
60 7/8” (1,546)
HRP4950T
50 (189)
PROPANE
38,000
39.0
3" (76) or 4" (102)
20” (508)
60 7/8” (1,546)
Thank You
for purchasing a Maytag water heater. Properly
installed and maintained, it should give you years of trouble
free service. It is strongly suggested that this new water heater
be professionally installed,
contact Maytag Customer Service
(1-800-788-8899) for recommended installers
.
Abbreviations Found In This Instruction Manual:
•
CSA - Canadian Standards Association
•
ANSI - American National Standards Institute
•
NFPA - National Fire Protection Association
•
ASME - American Society of Mechanical Engineers
•
GAMA - Gas Appliance Manufacturers Association
This gas-fired water heater is design certified by CSA
INTERNATIONAL under American National Standard/CSA
Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current
edition).
• Read the “Safety Precautions” section, page 3 of this manual
first and then the entire manual carefully. If you don’t follow
the safety rules, the water heater will not operate properly. It
could cause DEATH, SERIOUS BODILY INJURY AND/OR
PROPERTY DAMAGE.
This manual contains instructions for the installation,
operation, and maintenance of the gas-fired water heater. It
also contains warnings through out the manual that you must
read and be aware of. All warnings and all instructions are
essential to the proper operation of the water heater and
your safety. Since we cannot put everything on the first few
pages,
READ THE ENTIRE MANUAL BEFORE ATTEMPTING
TO INSTALL OR OPERATE THE WATER HEATER.
•
The installation must conform with these instructions and
the local code authority having jurisdiction. In the absence of
local codes, installations shall comply with the following:
In the United States
: The National Fuel Gas Code ANSI
Z223.1/NFPA 54. This publication is available from the
CSA International, 8501 East Pleasant Valley Rd, Cleveland
Ohio 44131, or The National Fire Protection Association,
1 Batterymarch Park, Quincy, MA 02269.
•
If after reading this manual you have any questions or do not
understand any portion of the instructions,
call Maytag
Customer Service at 1-800-788-8899 for an authorized
servicer.
•
Carefully plan the place where you are going to put the water
heater. Correct combustion, vent action, and vent pipe
installation are very important in preventing death from
possible carbon monoxide poisoning and fires, see
figure 1 and 2.
Examine the location to ensure the water heater complies
with the
Facts to Consider About the Location
section in this
manual.
•
For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation
procedures. Instructions may be obtained from your local
dealer, wholesaler, public utilities or California Office of the
State Architect, 400 P Street, Sacramento, CA 95814.
•
Massachusetts Code requires this water heater to be
installed in accordance with Massachusetts 248-CMR 2.00:
State Plumbing Code and 248-CMR 5.00. In the
Commonwealth of Massachusetts, this product must be
installed by a licensed plumber or gasfitter.
•
Complies with SCAQMD rule #1121 and districts having
equivalent NOx requirements.
CUSTOMER RESPONSIBILITIES
PRODUCT SPECIFICATIONS