28
BASIC
(6 different control scenarios to be tested)
11.1
M
AIN
C
ONTROLS
This procedure allows the installer to verify that all modes of operation are fully functional.
During the verification of a main control, make sure that all optional remote controls are inactive.
11.0 Overall Verification
Set the slider
Set condensation control
Results expected
switch to
dial to
fan speed
1
Off
maximum counterclockwise
motor off
2
Off
maximum clockwise
motor off
3
Min.
maximum counterclockwise
low speed
4
Min.
maximum clockwise
high speed
5
Max.
maximum counterclockwise
high speed
6
Max.
maximum clockwise
high speed
CONDENSATI0N CONTROL
AIR SUPPLY CONTRO
L
L
L
MIN.
MAX.
OFF
A
AIR
R
II
EXCHANGE
CH
HA
-20 C
-4
°
41
°
F
C O
F
Z N
E
SU
M
M
ER
VC0027
Set air supply
Set condensation control
Results expected
control to
dial to
Fan
Exchange Max speed
speed
indicator
indicator
(A)
(B)
1 Off maximum counterclockwise
off
off
off
2
Off
maximum clockwise
off
off
off
3 Min. maximum counterclockwise
low
on
off
4
Min.
maximum clockwise
high
on
on
5 Max. maximum counterclockwise
high
on
off
6
Max.
maximum clockwise
high
on
on
7 Intermittent maximum counterclockwise
off 40 min
off 40 min
off
low 20 min on 20 min
off
8
Intermittent
maximum clockwise
high
on
on
ELECTRONIC
(8 different control scenarios to be tested)
°
C
-4
°
F
-5
C
41
°
F
CONDENSATI0N CONTROL
AIR SUPPLY CONTRO
L
L
L
CONDENSATION CONTROL
MAXIMUM SPEED
AIR EXCHANGE IN PROGRESS
MIN.
MAX.
CONTINUOUS
CONTINUOUS
INTERMITTENTT
INTERMITTENT
20 MI
M N
.
N
N
ON
ON
40 MIN.
M
OFF
OF
C OM
Z O
E
SU
M
M
ER
VC0028
B
A
11.2
O
PTIONAL
C
ONTROL
First, turn OFF the main control device (Basic or Electronic) before checking the remote optional control.
20/40/60-
MINUTE PUSH
-
BUTTON TIMER
:
Activate the push button. Within 2 seconds, push one time for 20 minutes, two times for
40 minutes or three times for a 60-minute activation.
Results expected:
1.
Motor speed: high for 20, 40 or 60 minutes.
2.
Indicator light goes “ON” and flashes every 5 seconds (one time to indicate a
20-minute operation, two times for a 40-minute, and three times for a 60-minute
operation).
3.
Air exchange indicator light goes “ON” (Electronic wall control only).
NOTE: To stop activation, push one more time.
VC0046
20 min.
40 min.
60 min.