Maytag CWG3100AAS - 24

9

GAS CONVERSIONS

Gas conversions from Natural gas to LP gas or from LP gas to 

Natural gas must be done by a qualified installer. 

LP Gas Conversion

1.

Turn manual shutoff valve to the closed position.

2.

Unplug oven or disconnect power.

To Convert Gas Pressure Regulator

1.

Locate gas pressure regulator in bottom compartment.

IMPORTANT:

 Do not remove the gas pressure regulator.

2.

Unscrew the hex-shaped regulator cap from the regulator 

and remove the regulator pin.

A. To oven
B. Shutoff valve (closed position)

C. Gas supply line

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 

Examples of a qualified person include: 

licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.

A

B

C

A. Gas pressure regulator
B. Gas supply line

C. Electrical disconnect

D. Serial plate

E. Manual oven valve

F. Burner rating plate

G. Manifold pressure tap

A. Regulator pin
B. Regulator cap

A

B

C

D

E

F

G

A

B

Summary of Contents for CWG3100AAS - 24"Gas Single Oven

Page 1: ...e W10526072B You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is t...

Page 2: ...er WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detect...

Page 3: ...materials used will not discolor delaminate or sustain other damage This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable...

Page 4: ...ctrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA I...

Page 5: ...ient gas supply Pipe joint compounds that resist the action of LP gas must be used Do not use TEFLON tape With LP gas piping or tubing size can be 1 3 cm minimum Usually LP gas suppliers determine the...

Page 6: ...installation 2 To avoid floor damage set the oven onto cardboard prior to installation Do not use handle or any portion of the front frame or trim for lifting 3 Remove the shipping materials and tape...

Page 7: ...inst seal area of oven front frame when pushing oven into cabinet Do not push against outside edges 2 Push oven completely into cabinet and center oven into cabinet cutout A Gas pressure regulator B U...

Page 8: ...s no adjustment When the oven control is turned on a glow bar igniter heats and ignites the gas Check Operation of Oven s 1 Turn power on The time should flash in the display 2 Check that the oven doo...

Page 9: ...valve closed position C Gas supply line WARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP...

Page 10: ...te conversion has occurred 3 Adjust burner air shutter to the widest opening that will not cause the flame to lift or blow off the burner when cold NaturalGasConversion 1 Turn manual shutoff valve to...

Page 11: ...from inside the broiler cavity 2 Screw the burner orifice hood away from the pins There will be approximately 1 to 2 turns NOTE On units using Eaton Oven Safety Valve screw the burner orifice hood awa...

Page 12: ...12...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15...

Page 16: ...W10526072B 2015 All rights reserved 8 15...