Diagnostic Code Checking 

Code Description 

When 

Checked 

Detection 

1c1c 

Shorted key 

Always 

1 minute 

1c2c 

Keyboard tail disconnected 

Always 

1 minute 

1c31 

Cancel key circuit problem 

Always 

20 seconds 

1c6c 

EEPROM error 

When accessing EEPROM 

3 tries 

1c7c 

Control not calibrated 

Always 

3 tries 

1c8c 

Cooking program error 

Cook or clean programmed 

3 tries 

1d11 

Runaway temp (650° F), door unlocked 

Latch unlocked 

1 minute 

1d21 

Runaway temp (950° F), door locked 

Latch locked 

1 minute 

3d11 

Sensor open 

Cook or clean active 

20 seconds 

3d21 

Sensor shorted 

Cook or clean active 

20 seconds 

4d11 

Door switch position failure 

Clean or keyboard Lockout 

active 

1 minute 

4d51 

Door switch circuit failure 

Convect, Clean or Keyboard 

Lockout programmed 

1 minute 

9d11 

Latch will not lock 

Latch should be locked 

See Note 6 

9d21 

Latch will not unlock 

Latch should be unlocked 

See Note 6 

9d31 

Latch state unknown, both locked and unlocked 

Latch should be locked or when 

lock attempted 

See Note 6 

Diagnostic Code Handling 

Code 

Measurable 

What is Displayed 

Action Taken By Control 

1c1c Keypress 

Nothing 

Disables audible for affected key 
depression 
Disables all outputs 

1, 2

 

Disables lights and timers 

1c2c 

Keyboard loop improper value 

Nothing 

Disables audible for key depression 
Disables all outputs 

1

 

Disables lights and timers 

1c31 

Cancel key improper value 

BAKE flashes 

3

 

Disables all outputs for cavity 

1

 

1c6c 

No response from EEPROM 

Nothing 

Disables all outputs 

1

 

1c7c 

Calibration value out of range 

"CAL" in the time digits Completely disables oven 

4

 

1c8c 

CRC invalid 

Nothing 

Cancels active cook functions 

1d11 

Sensor resistance > 2237 Ohms 

BAKE flashes 

3

 

Disables all cook functions for cavity 

1d21 

Sensor resistance > 2787 Ohms 

BAKE flashes 

3

 

Disables all cook functions for cavity 

3d11 

Sensor resistance > Infinite Ohms 

BAKE flashes 

3

 

Disables all cook functions for cavity 

3d21 

Sensor resistance > 0 Ohms 

BAKE flashes 

3

 

Disables all cook functions for cavity 

4d11 

Door switch not closed when door is 
locked 

Nothing 

Disables Clean and Lockout 
functions 

5

 

4d51 

Door switch not open or closed 

Nothing 

Disables Convect, Clean, and 
Lockout functions 

4, 5 

Turn off light and disable light from 
door switch 

9d11 

Lock switch not closed 

LOCK flashes 

3

 

Disables Clean and Lockout 
functions 

4

 

9d21 

Unlock switch not closed 

LOCK flashes 

3

 

Disables Clean and Lockout 
functions 

4

 

9d31 

Lock and unlock switches both closed 

LOCK flashes 

3

 

Disables Clean and Lockout 
functions 

4

 

 

Summary of Contents for AGR5715QD

Page 1: ...in W C P Surface Burner BTU Nat LP Small 5 000 4 000 N A N A 5 000 4 000 Medium 9 200 9 100 9 200 9 100 9 200 9 100 Large 12 000 10 000 12 000 10 000 16 000 14 000 Oven Burner BTU Nat LP Bake 18 000 1...

Page 2: ...utolatch assembly with switch Disconnect wires and test for continuity per wiring diagram See wiring diagram for schematic layout Refer to Parts Manual for correct autolatch switch Door latch assembly...

Page 3: ...ound 120 VAC Not subject to polarity Holder orifice Verify gas pressure WCP Check orifice for debris 4 Natural 10 LP Propane Clean as necessary Spark ignition electrode Test for resistance of spark le...

Page 4: ...t M1 Factory default Press and hold Cancel and Keep Warm pads for 3 to 5 seconds Allows the clock to be reset to factory settings M1 12 hour off Control will automatically cancel any cooking operation...

Page 5: ...y will indicate the following Key Operation Bake Bake relay activated Broil Broil relay activated Keep Warm N A Cook Hold Last Diagnostic Code displayed Clean MDL relay activated lock and unlock Delay...

Page 6: ...de Measurable What is Displayed Action Taken By Control 1c1c Keypress Nothing Disables audible for affected key depression Disables all outputs 1 2 Disables lights and timers 1c2c Keyboard loop improp...

Page 7: ...ed and until the unlocked position is achieved The unlock position may be identified by a successful unlock switch closure or as the result of timing when the unlock switch is not functioning properly...

Page 8: ...ical shock personal injury or death disconnect power and gas to range before servicing unless testing requires power and or gas 16027222 May 2006 Replaces 16022499 2006 Maytag Services 8 Wiring Diagra...

Page 9: ...cal shock personal injury or death disconnect power and gas to range before servicing unless testing requires power and or gas May 2006 16027222 2006 Maytag Services Replaces 16022499 9 Schematic Diag...

Page 10: ...void risk of electrical shock personal injury or death disconnect power and gas to range before servicing unless testing requires power and or gas 16027222 May 2006 Replaces 16022499 2006 Maytag Servi...

Page 11: ...atic WARNING To avoid risk of electrical shock personal injury or death disconnect power and gas to range before servicing unless testing requires power and or gas May 2006 16027222 2006 Maytag Servic...

Page 12: ...id risk of electrical shock personal injury or death disconnect power and gas to range before servicing unless testing requires power and or gas 16027222 May 2006 Replaces 16022499 2006 Maytag Service...

Page 13: ...isk of electrical shock personal injury or death disconnect power and gas to range before servicing unless testing requires power and or gas May 2006 16027222 2006 Maytag Services Replaces 16022499 13...

Page 14: ...sk of electrical shock personal injury or death disconnect power and gas to range before servicing unless testing requires power and or gas 16027222 May 2006 Replaces 16022499 2006 Maytag Services 14...

Reviews: