Control Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
16027222
May
2006
Replaces 16022499
© 2006 Maytag Services
4
Controller Feature
Procedure
Results
M1
Oven temperature
adjustment
Press
BAKE
pad.
Enter
550
on the digit-pad.
Immediately press and hold
BAKE
pad for 3 to 5 seconds.
Oven can be adjusted from -35 to +35
degrees in 5-degree increments by
pressing
AUTOSET
pad. To avoid
over adjusting the oven, move
temperature 5 degrees each time.
Wait 4 seconds for the data entry timer
to expire to accept the change.
Temperature adjustment will be
retained even through a power failure
.
While increasing or decreasing oven
temperature, this does not affect self-
cleaning temperature.
M1
Temperature display
Press and hold
Cancel
and
Bake
pads for 3 to 5 seconds.
Toggles temperature display between °F
and °C.
M1
Clock display
Press and hold
Cancel
and
Clock
pads for 3 to 5 seconds.
Toggles clock display on and off.
M1
24-hour Clock
Press and hold
Cancel
and
Delay
pads for 3 to 5 seconds.
Toggles time display between 12 or 24
hour format.
M1
Factory default
Press and hold
Cancel
and
Keep
Warm
pads for 3 to 5 seconds.
Allows the clock to be reset to factory
settings.
M1
12-hour off
Control will automatically cancel any
cooking operation and remove all
relay drives 12 hours after the last pad
touch.
See Sabbath mode to disable.
M1
Sabbath mode
Hold
CLOCK
pad for 3 to 5 seconds to
activate Sabbath mode.
Hold
CLOCK
pad for 3 to 5 seconds to
disable Sabbath mode.
"SAb" flashes for 5 seconds.
Display returns to time of day.
All pad inputs are disabled except for
CANCEL
and
CLOCK
pads.
This mode disables the normal 12 hour
shutoff to allow operation of the bake
mode for a maximum of 72 hours.
M1
Child lock out
Press and hold
Cancel
and
Cook &
Hold
pads for 3 to 5 seconds.
"OFF"
will display where the temperature
normally appears.
"LOCK"
will display
flashing while door is locking.
To reactivate the control, press and
hold
Cancel
and
Cook & Hold
pads
for 3 to 5 seconds.
Safety feature that used to prevent
children from accidentally programming
the oven. It disables the electronic oven
control.
Child lockout features must be reset after
a power failure.
M1
Diagnostic code
display
Press and hold
Up Arrow
pad and
Power Up
the unit.
Cycle through the codes using the
number pads 1 through 5.
The last 5 diagnostic codes will be stored
in the non-volatile memory.
See
"Description of Error Codes"
for
explanation.