4

 

Controller Feature 

Procedure 

Results 

M1 

Oven temperature 
adjustment 

Press 

BAKE 

pad. 

Enter 

550

 on the digit-pad. 

Immediately press and hold 

BAKE

 

pad for 3 to 5 seconds. 
 
Oven can be adjusted from -35 to +35 
degrees in 5-degree increments by 
pressing 

AUTOSET

 pad. To avoid 

over adjusting the oven, move 
temperature 5 degrees each time. 
Wait 4 seconds for the data entry timer 
to expire to accept the change. 
Temperature adjustment will be 
retained even through a power failure

.

 

While increasing or decreasing oven 
temperature, this does not affect self-
cleaning temperature. 

M1 

Temperature display 

Press and hold 

Cancel

 and 

Bake

 

pads for 3 to 5 seconds. 

Toggles temperature display between °F 
and °C. 

M1 

Clock display 

Press and hold 

Cancel

 and 

Clock

 

pads for 3 to 5 seconds. 

Toggles clock display on and off. 

M1 

24-hour Clock 

Press and hold 

Cancel

 and 

Delay

 

pads for 3 to 5 seconds. 

Toggles time display between 12 or 24 
hour format. 

M1 

Factory default 

Press and hold 

Cancel

 and 

Keep 

Warm

 pads for 3 to 5 seconds. 

Allows the clock to be reset to factory 
settings. 

M1 

12-hour off 

Control will automatically cancel any 
cooking operation and remove all 
relay drives 12 hours after the last pad 
touch. 

See Sabbath mode to disable. 

M1 

Sabbath mode 

Hold 

CLOCK

 pad for 3 to 5 seconds to 

activate Sabbath mode. 
 
Hold 

CLOCK

 

pad for 3 to 5 seconds to 

disable Sabbath mode. 

"SAb" flashes for 5 seconds. 
Display returns to time of day. 
All pad inputs are disabled except for 

CANCEL

 and 

CLOCK

 pads. 

This mode disables the normal 12 hour 
shutoff to allow operation of the bake 
mode for a maximum of 72 hours. 

M1 

Child lock out 

Press and hold 

Cancel

 and 

Cook & 

Hold 

pads for 3 to 5 seconds. 

"OFF"

 

will display where the temperature 
normally appears. 

"LOCK"

 will display 

flashing while door is locking. 
To reactivate the control, press and 
hold 

Cancel

 and 

Cook & Hold 

pads

 

for 3 to 5 seconds.  

Safety feature that used to prevent 
children from accidentally programming 
the oven. It disables the electronic oven 
control. 
 
Child lockout features must be reset after 
a power failure. 

M1 

Diagnostic code 
display 

Press and hold 

Up Arrow

 pad and 

Power Up

 the unit. 

Cycle through the codes using the 
number pads 1 through 5. 

The last 5 diagnostic codes will be stored 
in the non-volatile memory. 
 
See 

"Description of Error Codes" 

for 

explanation. 

Summary of Contents for AGR5715QD

Page 1: ...in W C P Surface Burner BTU Nat LP Small 5 000 4 000 N A N A 5 000 4 000 Medium 9 200 9 100 9 200 9 100 9 200 9 100 Large 12 000 10 000 12 000 10 000 16 000 14 000 Oven Burner BTU Nat LP Bake 18 000 1...

Page 2: ...utolatch assembly with switch Disconnect wires and test for continuity per wiring diagram See wiring diagram for schematic layout Refer to Parts Manual for correct autolatch switch Door latch assembly...

Page 3: ...ound 120 VAC Not subject to polarity Holder orifice Verify gas pressure WCP Check orifice for debris 4 Natural 10 LP Propane Clean as necessary Spark ignition electrode Test for resistance of spark le...

Page 4: ...t M1 Factory default Press and hold Cancel and Keep Warm pads for 3 to 5 seconds Allows the clock to be reset to factory settings M1 12 hour off Control will automatically cancel any cooking operation...

Page 5: ...y will indicate the following Key Operation Bake Bake relay activated Broil Broil relay activated Keep Warm N A Cook Hold Last Diagnostic Code displayed Clean MDL relay activated lock and unlock Delay...

Page 6: ...de Measurable What is Displayed Action Taken By Control 1c1c Keypress Nothing Disables audible for affected key depression Disables all outputs 1 2 Disables lights and timers 1c2c Keyboard loop improp...

Page 7: ...ed and until the unlocked position is achieved The unlock position may be identified by a successful unlock switch closure or as the result of timing when the unlock switch is not functioning properly...

Page 8: ...ical shock personal injury or death disconnect power and gas to range before servicing unless testing requires power and or gas 16027222 May 2006 Replaces 16022499 2006 Maytag Services 8 Wiring Diagra...

Page 9: ...cal shock personal injury or death disconnect power and gas to range before servicing unless testing requires power and or gas May 2006 16027222 2006 Maytag Services Replaces 16022499 9 Schematic Diag...

Page 10: ...void risk of electrical shock personal injury or death disconnect power and gas to range before servicing unless testing requires power and or gas 16027222 May 2006 Replaces 16022499 2006 Maytag Servi...

Page 11: ...atic WARNING To avoid risk of electrical shock personal injury or death disconnect power and gas to range before servicing unless testing requires power and or gas May 2006 16027222 2006 Maytag Servic...

Page 12: ...id risk of electrical shock personal injury or death disconnect power and gas to range before servicing unless testing requires power and or gas 16027222 May 2006 Replaces 16022499 2006 Maytag Service...

Page 13: ...isk of electrical shock personal injury or death disconnect power and gas to range before servicing unless testing requires power and or gas May 2006 16027222 2006 Maytag Services Replaces 16022499 13...

Page 14: ...sk of electrical shock personal injury or death disconnect power and gas to range before servicing unless testing requires power and or gas 16027222 May 2006 Replaces 16022499 2006 Maytag Services 14...

Reviews: