8
INSTALLATION REQUIREMENTS
Tools and Parts
Parts supplied:
Water inlet hoses (2)
Inlet hose washers (4)
Service Keys
Drain Hose
Hose clamp
Foot Leveling (4)
(MYS20, MYS30, MYS40, MYS55,
MYS65 only)
LOCATION REQUIREMENTS
Forces transmitted by the washing machine
MYR20
MYR25
MYR30
MYR40
MYR55
MYR65
Static floor load (Kn - lb)
1.49 (334)
1.99 (447)
2.18 (489)
3.07 (688)
3.26 (731)
3.40 (764)
Dynamic floor load (Kn - lb)
2.42 (543)
4.01 (900)
5.12 (1,150)
5.60 (1,260)
7.52 (1,690)
8.82 (1,981)
Maximum vertical load (Kn - lb)
3.91 (877)
6.00 (1,347)
7.30 (1,639)
8.67 (1,948)
10.80 (2,421)
12.22 (2,745)
Dynamic load frequency (Hz)
13.97
13.20
13.17
11.59
11.55
11.59
G factor
200
200
200
200
200
200
Anchorage points
4
4
4
8
8
8
Min Concrete Thk. (mm - in)
100 (4)
100 (4)
150 (6)
150 (6)
200 (8)
200 (8)
Nut (4)
(MYS20, MYS30, MYS40, MYS55, MYS65 Only)
Filter Screen (2)
(MYR55, MYS55, MYR65, MYS65 only)
Washer
(4) (MYR20, MYR25, MYR30 only)
(8) (MYR40, MYR55, MYR65 only)