![MAYSER SG-EFS Operating Instructions Manual Download Page 17](http://html1.mh-extra.com/html/mayser/sg-efs/sg-efs_operating-instructions-manual_1747528017.webp)
011221 v3.11-RiA
Operating Instructions SG-EFS 104/4L
Page 17/17
SG-EFS 104/4L
AC 24 V
DC 24 V
Mechanical operating conditions
Cable terminals
4× 4-pin
4× 4-pin
Solid wire
1× 2.5 mm
2
or 2× 1.5 mm
2
1× 2.5 mm
2
or 2× 1.5 mm
2
Strand with sheath
1× 2.5 mm
2
or 2× 1.5 mm
2
1× 2.5 mm
2
or 2× 1.5 mm
2
Tightening torque
0.5 to 0.6 Nm
0.5 to 0.6 Nm
IEC 60529: protection class
IP20
IP20
Max. humidity (23 °C)
95%
95%
Operating temperature
-25 °C to +55 °C (UL: up to +40 °C)
-25 °C to +55 °C (UL: up to +40 °C)
Storage temperature
-25 °C to +55 °C
-25 °C to +55 °C
Impact resistance in operation
2 g
2 g
Dimensions (W × H × D)
22.5 × 99 × 114.5 mm
22.5 × 99 × 114.5 mm
Weight
180 g
180 g
Technical data