![MAYSER SG-EFS Operating Instructions Manual Download Page 16](http://html1.mh-extra.com/html/mayser/sg-efs/sg-efs_operating-instructions-manual_1747528016.webp)
Page 16/17
Operating Instructions SG-EFS 104/4L
011221 v3.11-RiA
SG-EFS 104/4L
AC 24 V
DC 24 V
Testing basis
EN 12978, ISO 13849-1, ISO 13856-1, ISO 13856-2, ISO 13856-3
Connecting voltage U
S
Nominal voltage
AC 24 V
DC 24 V
Voltage tolerance
-10% to +10%
-10% to +10%
Rated current
280 mA
86 mA
Nominal frequency
50 to 60 Hz
–
External fuse protection
–
–
Power consumption
< 7 VA
< 3 W
Times
Reaction time t
a
< 50 ms
< 30 ms
Restart time t
w
< 500 ms
< 500 ms
Safety classifications
ISO 13856: reset function
With/without
With/without
ISO 13849-1:2015
Category 3 PL e
Category 3 PL e
MTTF
D
100 a
100 a
DC
avg
90%
90%
B
10D
(load: DC 24 V / 2 A)
4× 10
5
4× 10
5
n
op
(assumption)
52560/a
52560/a
CCF
Requirements met
Requirements met
IEC 60664-1: creep distance and
air gap
Soiling degree 2, overvoltage
category III / 250 V, basic insulation
Soiling degree 2, overvoltage
category III / 250 V, basic insulation
Inputs
Sensor
Y11, Y12 and Y21, Y22
Y11, Y12 and Y21, Y22
Short-circuit resistance
≤ 400 ohms
≤ 400 ohms
Line resistance
≤ 10 ohms
≤ 10 ohms
Line length (max.)
100 m
100 m
Switching thresholds
Sensor activated
< 1k3 ohms
< 1k3 ohms
Cable break
–
–
Outputs
OSSDs 1, 2 and 3 (NO contact)
13, 14 and 23, 24 and 33, 34
13, 14 and 23, 24 and 33, 34
Signal output (NC contact)
41, 42
41, 42
EN 60947-5-1: utilisation
category
AC-12: 250 V / 5 A
DC-12: 30 V / 5 A
AC-12: 250 V / 5 A
DC-12: 30 V / 5 A
Switching voltage (max.)
AC 230 V
DC 24 V
AC 230 V
DC 24 V
Switching current (max.)
5 A 5 A
5 A 5 A
Total current (max.)
13.8 A 13.8 A
13.8 A 13.8 A
Switching capacity (max.)
1150 VA 120 W
1150 VA 120 W
Switching operations, mechanical > 1× 10
7
> 1× 10
7
Switching operations, electrical
> 1× 10
5
(DC 24 V / 2 A)
> 1× 10
5
(DC 24 V / 2 A)
External fuse protection
for contacts
NO contact
6.3 A quick-acting
6.3 A quick-acting
NC contact
4 A Neozed gL/gG
4 A Neozed gL/gG
Technical data