Mayr ROBA-takt Installation And Operational Instructions Download Page 3

Installation and Operational Instructions for

 

ROBA

®

-takt clutch brake unit with 'energise to engage' brake

 

Type 67_.0_ _._   Sizes 3 to 7

 

(B.6.1.EN)

 

21/06/2018 GC/SI/EI/SU

 

Chr. Mayr GmbH + Co. KG

 

 

Eichenstraße 1, D-87665 Mauerstetten, Germany

 

 

Tel.: +49 8341 804-0, Fax: +49 8341 804-421

 

Page 3 of 7 

www.mayr.com

E-Mail

[email protected]

 

 

Safety Regulations 

These Safety Regulations are user hints only and may not be complete!

 

 

Climate Conditions 

The ROBA

®

-takt clutch brake unit is suitable for applications with 

an ambient temperature of between -20 °C and +40 °C. 
 

CAUTION 

Reduction in torque possible 

Condensation can form on the friction surfaces 
and cause a loss in torque: 

 

due to fast changes in temperature 

 

at temperatures of around or under 
freezing point 

The user is responsible for taking appropriate 
countermeasures (e.g. forced convection, 
heating, drain screw).

 

 

CAUTION 

Malfunction of ROBA

®

-takt clutch brake unit 

possible 

Condensation can form on the friction surfaces 
and cause malfunctions: 

 

at temperatures around or under freezing 
point, the clutch brake unit can freeze over 
and not disengage any more. 

The user is responsible for taking appropriate 
countermeasures (e.g. forced convection, 
heating, drain screw).

 

 

Intended Use 

mayr

 

®

-clutch brake units have been developed, manufactured 

and tested in compliance with the DIN VDE 0580 standard and in 
accordance with the EU Low Voltage Directive as electromagnetic 
components. During installation, operation and maintenance of the 
product, the requirements for the standard must be observed. 

mayr

 

®

-clutch brake units are for use in machines and systems 

and must only be used in the situations for which they are ordered 
and confirmed. Using them for any other purpose is not allowed. 
 

Earthing Connection 

The clutch brake unit is designed for Protection Class I. This 
protection covers not only the basic insulation, but also the 
connection of all conductive parts to the protective conductor (PE) 
on the fixed installation. If the basic insulation fails, no contact 
voltage will remain. Please carry out a standardised inspection of 
the protective conductor connections to all contactable metal 
parts! 
 

Class of Insulation F (+155 °C) 

The insulation components on the magnetic coils are 
manufactured at least to class of insulation F (+155 °C). 
 

Protection IP55 

Dust-proof and protected against contact as well as against jet 
water from a nozzle coming from any direction. 
 

Storage of ROBA

®

-takt clutch brake units 

  Store the clutch brake units in a horizontal position, in dry 

rooms, dust and vibration-free. 

  Relative air humidity < 50 %. 

  Temperature without major fluctuations within a range from  

-20 °C up to +40 °C. 

  Do not store in direct sunlight or UV light. 

  Do not store aggressive, corrosive substances (solvents / 

acids / lyes / salts / oils / etc.) near to the brakes. 

For longer storage of more than 2 years, special measures are 
required (please contact the manufacturer). 

Storage acc. DIN EN 60721-3-1 (including the limitations / 
additions described above): 1K3; 1Z1; 1B1; 1C2; 1S3; 1M1 
 

Handling 

Before installation

, the clutch brake unit must be inspected and 

found to be in proper condition. 
The clutch brake unit function must be inspected both 

once 

attachment has taken place

 as well as 

after longer system 

downtimes

, in order to prevent the drive starting up against 

possibly seized friction surfaces. 
 

User-implemented Protective Measures: 

  Please cover moving parts to protect 

against injury 

through seizure

  Attach a cover to protect 

against injury through high 

temperatures 

on the housing 

 

Protection circuit: 

When using DC-side switching, the coils 

must be protected by a suitable protection circuit according 
to VDE 0580, which is integrated in 

mayr

®

-rectifiers. To 

protect the switching contact from consumption when using 
DC-side switching, additional protective measures are 
necessary (e.g. series connection of switching contacts). 
The switching contacts used should have a minimum contact 
opening of 3 mm and should be suitable for inductive load 
switching. Please make sure on selection that the rated 
voltage and the rated operating current are sufficient. 
Depending on the application, the switching contact can also 
be protected by other protection circuits (e.g. 

mayr

 

®

-spark 

quenching unit, half-wave and bridge rectifiers), although this 
may of course then alter the switching times. 

  Install additional protective measures 

against corrosion

 if 

the clutch brake unit is subject to extreme ambient 
conditions or is installed in open air conditions, unprotected 
from the weather. 

  Take precautions 

against freeze-up of the friction 

surfaces

 in high humidity and at low temperatures. 

 
 

 
 

 

 

 

Summary of Contents for ROBA-takt

Page 1: ...according to the EMC Only after integration of the product into an overall system can this be evaluated in terms of the EMC For electronic equipment the evaluation has been verified for the individual...

Page 2: ...m into operation Never bring them into contact with water or other fluids Please observe the EN 60204 1 requirements for electrical connection when using in machines Only carry out installation mainte...

Page 3: ...magnetic coils are manufactured at least to class of insulation F 155 C Protection IP55 Dust proof and protected against contact as well as against jet water from a nozzle coming from any direction S...

Page 4: ...N EN 61000 6 4 Interference emission DIN EN 61000 6 2 Interference immunity Liability The information guidelines and technical data in these documents were up to date at the time of printing Demands o...

Page 5: ...clutch is energised the magnetic coil in the brake must be voltage free The rotating drive shaft 2 attracts the armature disk The torque is transmitted via frictional locking from the drive shaft 2 v...

Page 6: ...ation Clutch Brake Diagram 1 The slope separation avoids simultaneous occurrence of clutch and braking torques Table 1 ROBA takt Size 3 4 5 6 7 Slope separation with overexcitation ms 29 33 43 65 106...

Page 7: ...ue to the strength of the shaft force application in the shaft centre ROBA takt Size 3 4 5 6 7 Radial force F N N Drive shaft without IEC flange 436 547 681 819 1149 Output shaft without IEC flange 78...

Reviews: