Installation and Operational Instructions for EAS
®
-compact
®
Ratchetting clutch, Type 49_._ _0._
Size 4
Synchronous clutch, Type 49_._ _5._
Size 4
(B.4.14.4.EN)
17/03/2021 TK/GC/NU
Chr. Mayr GmbH + Co. KG
Eichenstraße 1, D-87665 Mauerstetten, Germany
Phone: +49 8341 804-0, Fax: +49 8341 804-421
Page 14 of 22
Limit Switch Installation
The switching direction arrow on the housing lid of the mechanical
limit switch faces in the direction of the adjusting nut (4) or in the
thrust washer (3) stroke direction, Fig. 1. Adjust the switch
distances for the contactless and mechanical limit switch acc. Fig.
13 or Fig. 14. The distance of the thrust washer (3) to the
switching point can be adjusted using a hexagon head screw,
wrench opening 7 (Figs. 13 and 14).
Fig. 13: contactless limit switch
Fig. 14: mechanical limit switch
Switching
direction