TECHNICAL SPECIFICATIONS  

 

Model 

No. 

Input 

Max. Charging 

Output 

Engine 

Start 

For Battery 

Capacity 

Fuse 

Mains Plug 

MP7212  230V AC  50Hz 180 Watt 

12V DC 3A / 12A        

24V DC 3A / 6A  

75A 

12V 6-200 Ah 
24V 6-100Ah 

13A 

MP7220  230V AC  50Hz 270 Watt 

12V DC 3A / 20A          
24V DC 3A / 12A  

150A 

12V 6-300 Ah 
24V 6-150Ah 

13A 

 

We declare that this product conforms to the following standards  

EN60335-1:2012+A11:2014+A13:2017 
EN60335-2-29:2004+A2:2010, EN62233:2008. 
EN55014-1:2017, EN55014-2:2015, EN61000-3-2:2014,  
EN61000-3-3:2013, and the following Directives 73/23 CEE, 93/68 CEE, 
2004/108/EC, 2002/95/EC (ROHS) 

 

 

Technical Manager Maypole Ltd November 2018 
 

Email: 

[email protected]

 

Web: 

www.maypole.ltd.uk

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

17

 

Summary of Contents for MP7212

Page 1: ...rolled Suitable for all 12 or 24 Volt lead acid batteries including deep cycle AGM and Gel INSTRUCTION MANUAL Please read and follow this operating manual and all safety instructions for the batteries...

Page 2: ...user serviceable parts in this product other than the fuse in the plug Locate the charger as far away from the battery being charged as the cables will permit The use of an extension cord is NOT recom...

Page 3: ...CHARGE RATE selection button for selecting the charging current and charging voltage 5 CHARGED LED lights up when the battery is fully charged 6 CHARGING LED lights up during charging 7 REVERSE POLAR...

Page 4: ...breaking battery connections Ensure the battery poles are clean Connect the battery clips to the battery in the following order First connect the positive charging lead RED to the positive post of th...

Page 5: ...d from the battery ABORTED CHARGES lf charging cannot be completed normally charging will be aborted The digital display may show an Error code To reset the charger after an aborted charge unplug the...

Page 6: ...y incorrectly not connected Unplug charger and check the connections Incorrect battery voltage 12 24V selected Unplug charger and wait for the LEDs to go out Reconnect the charger and select the corre...

Page 7: ...13A MP7220 230V AC 50Hz 270 Watt 12V DC 3A 20A 24V DC 3A 12A 150A 12V 6 300 Ah 24V 6 150Ah 13A We declare that this product conforms to the following standards EN60335 1 2012 A11 2014 A13 2017 EN60335...