CHARGING RATE SELECTION

 

Do not overcharge a battery, refer to the battery manufacturers charging instructions. 
The charger always starts up in the 

AUTOMATIC

 slow charge mode.  

Repeatedly pressing the 

CHARGING RATE MODE

 button (4) will allow you to cycle through the 

following charging programs: 
3A Intended Use for slow charging automotive batteries or charging motorcycle batteries. 
Fast Charge: Intended Use for charging medium automotive batteries. Faster charging of small-
to-medium capacity automotive, marine, deep cycle, and farm tractor batteries  
Engine Start 12V - 75A or 150A: Intended Use Helps start vehicles and equipment with a weak 
battery. 
During Charging: You may repeatedly press the DISPLAY MODE button (8) to display the 
Charging voltage (V), Charge in (%) and the Charging current (A). You may also repeatedly press 
the BATTERY TYPE button (9) to select the battery type. 

 

MAINTENANCE MODE

 

Once 

the battery is fully charged, the “CHARGED” LED (5) will light up and the “Charging” LED (6) 

goes out, the charger will automatically go into Maintenance (Float) mode to maintain the charge 
in the battery and protect from overcharging. This function allows the charger to be permanently 
connected. 

WHEN CHARGING IS COMPLETE

 

 

To disconnect the charger, first switch off the mains supply, unplug the charger from the mains 
socket and then disconnect the clips in the following order:  

Remove the

 negative (BLACK lead) first. 

Then disconnect the 

positive (RED lead)

 from the 

battery. 

ABORTED CHARGES 

lf charging cannot be completed normally, charging will be aborted.The digital display may show 
an Error code. To reset the charger after an aborted charge, unplug the charger, disconnect the 
battery and then after checking the battery and connections reconnect correctly. 

 

OVERHEAT PROTECTION 

The charger is designed to shut itself off if overheating is detected. Once the charger cools down, it 
will resume charging automatically. 

 

ENGINE START FUNCTION 

The charger’s engine start function (3) can be used to help start vehicles with a weak battery. In 
very low temperatures or if the battery voltage is below 1.5 V charge the battery at least 5 minutes 
before jump starting. 
1. Connect the charger as described under “Connection”. 
2. When charging commences, repeatedly press the 

CHARGE RATE

 button (4) to select 

“ENGINE START” mode LED (3). 
The display shows the current battery voltage. The battery will be charged at 5 A until the engine 
is started. 

Note:

 The engine start mode will automatically stop after approx. 30 seconds to prevent damage 

to the device. 
3. Try starting the vehicle. 

Note:

 Try starting for max. 5 seconds. Wait approx. 3 minutes before trying to start it again to 

allow the charger and battery to cool down. 
4. Engine start mode will be disabled for 3 minutes. The display will show a 180 second 
countdown and the battery will be charged at 5 A until the engine is start mode is available.  
5. Once the engine has started, unplug the mains plug from the 230 V mains socket. 
6. Disconnect the black (-) terminal connection cable with clamp from the negative battery 
terminal. 
7. Disconnect the red (+) terminal connection cable with clamp from the positive battery terminal. 
 

13

 

9

 

11

 

10

 

12

 

Summary of Contents for MP7212

Page 1: ...rolled Suitable for all 12 or 24 Volt lead acid batteries including deep cycle AGM and Gel INSTRUCTION MANUAL Please read and follow this operating manual and all safety instructions for the batteries...

Page 2: ...user serviceable parts in this product other than the fuse in the plug Locate the charger as far away from the battery being charged as the cables will permit The use of an extension cord is NOT recom...

Page 3: ...CHARGE RATE selection button for selecting the charging current and charging voltage 5 CHARGED LED lights up when the battery is fully charged 6 CHARGING LED lights up during charging 7 REVERSE POLAR...

Page 4: ...breaking battery connections Ensure the battery poles are clean Connect the battery clips to the battery in the following order First connect the positive charging lead RED to the positive post of th...

Page 5: ...d from the battery ABORTED CHARGES lf charging cannot be completed normally charging will be aborted The digital display may show an Error code To reset the charger after an aborted charge unplug the...

Page 6: ...y incorrectly not connected Unplug charger and check the connections Incorrect battery voltage 12 24V selected Unplug charger and wait for the LEDs to go out Reconnect the charger and select the corre...

Page 7: ...13A MP7220 230V AC 50Hz 270 Watt 12V DC 3A 20A 24V DC 3A 12A 150A 12V 6 300 Ah 24V 6 150Ah 13A We declare that this product conforms to the following standards EN60335 1 2012 A11 2014 A13 2017 EN60335...