MayPole MP7212 Instruction Manual Download Page 4

DDDDDDD

DDDD

ww

w.maypole.ltd.uk

 

MAMMMMMMMMM

pole.ltd.uk

 

www.maypole.ltd.uk

 

 

 

 

DESCRIPTION OF LED INDICATORS AND DISPLAY 

 

 

The charger starts with the 

MAIN DISPLAY

 (1) in the 

AMPS

 mode.  

Pressing the 

DISPLAY MODE 

button (8) repeatedly will allow you to cycle through to the other 

modes, 

VOLTAGE

 and 

BATTERY CAPACITY %

 . The LEDs (11) will indicate which mode is 

selected, the digital display will indicate the corresponding value for each mode.  

DESCRIPTION OF MAIN DISPLAY MODES 

 

VOLTS

 

The display will show the charging voltage supplied by the charger, this is usually higher than the 
battery's resting voltage. 

 

AMPS

 

This mode shows the charging current being supplied by the charger and not the charge rate 
selected. The charger detects and delivers the correct amount of amperage needed to charge the 
connected battery. 

 

%

 

 

Battery capacity is the approximate percentage of the full battery capacity. At less than 50% 
battery capacity, the 

MAIN DISPLAY

 will read 

LO

As the battery is charged the display will increase in 10% increments between 50% and 90% 
capacity. At full charge, the display will read 

FUL. 

 

PREPARATION OF THE BATTERY 

Refer to the vehicle manufacturer

’s handbook for battery maintenance and charging guidelines.

 

If the battery must be removed from the vehicle before charging, ensure all other electrical loads 
in the vehicle are switched off. Always disconnect the earthed connector from the battery first.

        

 

 
 

CONNECTION 

 

Always disconnect the mains supply before making or breaking battery connections.  Ensure the 
battery poles are clean. Connect the battery clips to the battery in the following order: 

First connect the positive charging lead (RED) to the positive post of the battery   
(, +ve or P). 

Then for vehicles with the battery still installed: connect the negative charging lead (BLACK)  to 
the vehicle chassis (marked -, -ve or N), well away from the battery, fuel line, hot  or moving parts. 

For batteries removed from the vehicle:  Connect the negative charging lead (BLACK) to the 
negative post of the battery (marked -, -ve or N). 

After connecting the clips, rotate them slightly so as to remove any dirt or oxidization, thus 
ensuring a good contact. The charger must now be connected to the mains supply. 

CHARGING

 

  

Warning! When correctly connected to a battery and to the mains supply, the charger will detect 
the battery voltage (12V-24V) and display 

the voltage measured on the “

Main Display

” (1). 

Charging will then start automatically, always commencing with the slow charge rate for the 
detected Voltage and Standard Battery type. 

This will illuminate one of Charging Voltage and Current display LEDs (2) and the 

Standard

 

battery type LED in display (10).  

The “

CHARGING

” LED (6) will light up, the charging process is then fully automatic. 

Note: 

Verify the device’s pre-set charging voltage (12V or 24V) corresponds with the connected battery. 
The charger is equipped with a microprocessor (MCU - Micro Computer Unit) and features fully 
automatic diagnostic, charging, and maintenance functions. If the wrong battery voltage is set or 
the battery is defective, it will not continue to 

charge and the “

REVERSE POLARITY

 LED (7) will 

light up (also see “Troubleshooting”). 

6

 

5

 

4

 

7

 

Summary of Contents for MP7212

Page 1: ...rolled Suitable for all 12 or 24 Volt lead acid batteries including deep cycle AGM and Gel INSTRUCTION MANUAL Please read and follow this operating manual and all safety instructions for the batteries...

Page 2: ...user serviceable parts in this product other than the fuse in the plug Locate the charger as far away from the battery being charged as the cables will permit The use of an extension cord is NOT recom...

Page 3: ...CHARGE RATE selection button for selecting the charging current and charging voltage 5 CHARGED LED lights up when the battery is fully charged 6 CHARGING LED lights up during charging 7 REVERSE POLAR...

Page 4: ...breaking battery connections Ensure the battery poles are clean Connect the battery clips to the battery in the following order First connect the positive charging lead RED to the positive post of th...

Page 5: ...d from the battery ABORTED CHARGES lf charging cannot be completed normally charging will be aborted The digital display may show an Error code To reset the charger after an aborted charge unplug the...

Page 6: ...y incorrectly not connected Unplug charger and check the connections Incorrect battery voltage 12 24V selected Unplug charger and wait for the LEDs to go out Reconnect the charger and select the corre...

Page 7: ...13A MP7220 230V AC 50Hz 270 Watt 12V DC 3A 20A 24V DC 3A 12A 150A 12V 6 300 Ah 24V 6 150Ah 13A We declare that this product conforms to the following standards EN60335 1 2012 A11 2014 A13 2017 EN60335...

Reviews: