24 1000 1500 Windlass Vetus-Maxwell APAC Ltd
Below Deck
Every three months.
The under deck components should be sprayed, preferably with CRC 3097 “Long Life” or alternatively,
CRC6-66 or WD40.
Particular attention should be paid to electric motors, including the motor terminals, footswitch terminals,
terminals on the Reversing Solenoid plus the battery and isolator terminals.
Gearbox
Every 3 months, check level of oil in gearbox using the sight glass. If necessary top up as per step 4 of
the installation procedure”.
The gearbox is a self-contained sealed unit. We recommend that the gearbox be removed and serviced
by an authorised Maxwell service technician every three years. Visit our website
(www.maxwellmarine.com) for a list of service centres and agents.
Motor
DC and Hydraulic Motors
For maximum protection, we recommend that the motor and electrical connections be sprayed
periodically with CRC Soft Seal.
The motor can be removed from the gearbox by undoing two bolts and washers.
A replaceable roll pin is a press fit in the output end of the drive shaft.
12V and 24V Motors
Providing the windlass is properly installed with the Maxwell Overload Control Box and Breaker Panel,
and the windlass is not abused, trouble free operation can be expected.
Remove the brush cover from the motor. Clean out accumulated carbon dust using a compressed air
hose.
Check and replace brushes if worn.
Remove any rust build up from the casing and paint with a suitable coating
DO NOT wrap the motor with grease cloth as this prevents the cooling of the motor
Replacement brush sets are available – order:
Part No. P100807 – 12 Volt.
Part No. P100808 – 24 Volt.
Summary of Contents for VW 1000 100TDC
Page 1: ...1000 1500 Windlass Manual ...
Page 9: ...Vetus Maxwell APAC Ltd 1000 1500 Windlass 7 VWC and VWCLP Windlass Parts List ...
Page 19: ...Vetus Maxwell APAC Ltd 1000 1500 Windlass 17 Wiring schematic series wound motor ...
Page 20: ...18 1000 1500 Windlass Vetus Maxwell APAC Ltd Wiring schematic Hydraulics ...
Page 21: ...Vetus Maxwell APAC Ltd 1000 1500 Windlass 19 Wiring schematic Hydraulic motor ...
Page 29: ...Vetus Maxwell APAC Ltd 1000 1500 Windlass 27 Dimensions VWC ...
Page 30: ...28 1000 1500 Windlass Vetus Maxwell APAC Ltd Dimensions VW ...
Page 31: ...Vetus Maxwell APAC Ltd 1000 1500 Windlass 29 Dimensions VW horizontal arrangement ...
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ......
Page 38: ......
Page 39: ......