Vetus-Maxwell APAC Ltd 1000 1500 Windlass 25
Trouble Shooting Guide
Windlass does not operate when activated
•
Check that the breaker/isolator panel is "On."
•
Check the connections to the following:
•
Remote up/down control panel and footswitches (if fitted)
•
Circuit breaker/isolator panel
•
Reversing solenoid
•
Windlass motor
•
Check the battery condition by operating other electrical equipment.
•
Check that the solenoid is working. You should hear the solenoid click when activated.
Motor is working but the chainwheel does not rotate
•
Check that the clutch nut is not too loose, causing slippage.
•
Check that the chainwheel is not jammed with the chain. If necessary, reverse the windlass to free
the jam.
•
Check that the key between the shaft and the gearbox is installed.
•
If the windlass does not rotate smoothly or there is excessive noise, the gearbox may be
damaged.
•
Check the motor drive pin by unbolting the motor from the gearbox.
Summary of Contents for VW 1000 100TDC
Page 1: ...1000 1500 Windlass Manual ...
Page 9: ...Vetus Maxwell APAC Ltd 1000 1500 Windlass 7 VWC and VWCLP Windlass Parts List ...
Page 19: ...Vetus Maxwell APAC Ltd 1000 1500 Windlass 17 Wiring schematic series wound motor ...
Page 20: ...18 1000 1500 Windlass Vetus Maxwell APAC Ltd Wiring schematic Hydraulics ...
Page 21: ...Vetus Maxwell APAC Ltd 1000 1500 Windlass 19 Wiring schematic Hydraulic motor ...
Page 29: ...Vetus Maxwell APAC Ltd 1000 1500 Windlass 27 Dimensions VWC ...
Page 30: ...28 1000 1500 Windlass Vetus Maxwell APAC Ltd Dimensions VW ...
Page 31: ...Vetus Maxwell APAC Ltd 1000 1500 Windlass 29 Dimensions VW horizontal arrangement ...
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ......
Page 38: ......
Page 39: ......