Waste Collection Box

the waste collection box should be checked daily and emptied as required by 

undoing the 2

thumbscrews and pulling the dust draw out.

(see image below)

Dust Mesh

the top cover should be lifter every 4 weeks to check no excessive build up of dust 

is on the

mesh filter.

(see image below)

Filter Clean

if a filter clean option is fitted please connect to a 6bar air supply. the cleaning is 

only active when the yellow button is pressed on the front of the machine. (see 

image below)

1. Use the handle on the

hood to position the hood

over the working area.

2. Ensure that the hood is

within 8” (200mm) as

labelled on the hood:

1. Ensure the unit is switched on.

PLEASE NOTE

The capture distance may differ from the commissioning value. Your Annual LEV 

Thorough examination and test will highlight any change.

Filters

 

When removing filters please ensure that the correct PPE is worn to 

 

protect against inhalation and Skin contact with contaminate.

The filtration media will require changing at suitable intervals. The filters are 

disposable and must be thrown away after use. The life of the filters will vary greatly 

depending upon the usage of the filter. As a guideline the filters should be replaced 

after 2000 hours approx. continuous use.

THIS HOOD MUST BE PLACED NO 
MORE THAN    

200mm

       FROM 

THE SOURCE OF EMMISSIONS

DIRECTIONS FOR USE