MAXVAC.COM
MAXVAC.COM
WFE 1800 | 2200 | 4000
WFE 1800 | 2200 | 4000
9
8
Waste Collection Box
the waste collection box should be checked daily and emptied as required by
undoing the 2
thumbscrews and pulling the dust draw out.
(see image below)
Dust Mesh
the top cover should be lifter every 4 weeks to check no excessive build up of dust
is on the
mesh filter.
(see image below)
Filter Clean
if a filter clean option is fitted please connect to a 6bar air supply. the cleaning is
only active when the yellow button is pressed on the front of the machine. (see
image below)
1. Use the handle on the
hood to position the hood
over the working area.
2. Ensure that the hood is
within 8” (200mm) as
labelled on the hood:
1. Ensure the unit is switched on.
PLEASE NOTE
The capture distance may differ from the commissioning value. Your Annual LEV
Thorough examination and test will highlight any change.
Filters
When removing filters please ensure that the correct PPE is worn to
protect against inhalation and Skin contact with contaminate.
The filtration media will require changing at suitable intervals. The filters are
disposable and must be thrown away after use. The life of the filters will vary greatly
depending upon the usage of the filter. As a guideline the filters should be replaced
after 2000 hours approx. continuous use.
THIS HOOD MUST BE PLACED NO
MORE THAN
200mm
FROM
THE SOURCE OF EMMISSIONS
DIRECTIONS FOR USE