Maxtor Atlas 10K V
5-39
Table 5-59
Unit Attention Condition Page (Page 0)
5.12.6
Read-Write Error Recovery Page (01h)
The Read-Write Error Recovery page controls the drive’s response to error
conditions that arise during the course of READ (6), READ (10), WRITE (6),
WRITE (10) command processing and during the write portion of WRITE AND
VERIFY command processing. The Read-Write Error Recovery page format and
field descriptions are described in Table 5-60 and Table 5-61 respectively.
Table 5-60
Read-Write Error Recovery Page-(Page 1)
Field
Default Value
Description
PS
1
Parameters Savable. This bit is only used with the MODE SENSE com-
mand. A returned value of 1 indicates that the target is capable of sav-
ing the page in a non-volatile, vendor-specific location. The bit is
reserved with the MODE SELECT command.
DUA
0
Disable Unit Attention. When set to the default value of 0, the drive re-
ports a CHECK CONDITION for any UNIT ATTENTION condition
(power-on, SCSI bus reset, etc.)
Bit
Byte
7
6
5
4
3
2
1
0
0
PS
Rsvd
Page Code (01h)
1
Page Length (0Ah)
2
AWRE
ARRE
TB
RC
EER
PER
DTE
DCR
3
Read Retry Count
4
Correction Span
5
Head Offset Count
6
Data Strobe Offset Count
7
Reserved
8
Write Retry Count
9
Reserved
10 – 11
Recovery Time Limit
Summary of Contents for Atlas 10K V
Page 1: ...Maxtor Atlas 10K V Product Manual September 6 2005 Revision 3 PN 000001911...
Page 39: ...Maxtor Atlas 10K V 3 15...
Page 48: ...3 24 Maxtor Atlas 10K V Figure 3 9 Crosswise Airflow Cooling Below Unit Above Unit...
Page 125: ...Maxtor Atlas 10K V 5 67 21 23 Reserved...
Page 147: ...Maxtor Atlas 10K V 5 89 22 23 MSB Extent Length LSB...
Page 214: ...5 156 Maxtor Atlas 10K V...