5-126
Maxtor Atlas 10K V
0x04
Hdwe Error
0x40
0x80
Unknown HW problem
0x40
0x82
Hardware Bug Check (check Info field)
0x40
0x83
Failed HDA test.
0x40
0x84
Failed PCB test.
0x40
0x85
EDC check failed.
0x40
0x86
Controller FIFO over/underflow error.
0x40
0x88
DIAG: Drive failed to read servowriter serial number.
0x40
0x89
DIAG: Failed XOR test.
0x40
0x90
EDC Check Failed 0
0x40
0x91
EDC Check Failed 1
0x40
0x92
EDC Check Failed 2
0x40
0x93
EDC Check Failed3
0x40
0x8A
Servo restart failed after set RPM command
0x40
0x8C
LBA mismatch error
0x40
0x8D
ETM test failure, drive failed to spin
0x40
0x8E
Could not achieve target RPM
0x40
0xA0
Test did not complete
0x40
0xA1
Test completed successfully, but failed.
0x40
0xA2
Invalid parameter was received.
0x40
0xA3
Invalid data in servo record. Prevented algorithm from completing.
0x40
0xA4
Servo record did not complete
0x40
0xA5
Read seek failed
0x40
0xA6
Write seek failed
0x40
0xA7
Raw seek failed
0x40
0xA8
Servo Diagnostic Test running.
0x40
0xA9
Invalid 97/98 super cmd seq. Must send 97 before 98
0x40
0xAA
Super Command 97 already running
0x40
0xAB
Complex magnitude is zero
0x40
0xAC
Could not complete the low-level BCV write function
0x40
0xAD
Got a divide by zero error in complex divide.
0x40
0xAE
WGATE negated due to shock or bump during BCV write
0x40
0xAF
Servo Death occurred during a BVC write operation
0x40
0xB0
Seek command completion timeout occurred
0x40
0xB1
Read an impossibility high number of good BCVS on this
0x40
0xB2
No read passes resulted in enough test BCVs being read
0x40
0xB3
The last read pass for test BCVs was good but shouldn’t be
0x40
0xB4
DestinationLoc expected vs actual mismatch. servo death recovery
0x44
0x00
Logical assertion (firmware consistency check)
0x44
0x84
Insufficient buffer memory for operation
0x90
0x01
Serial Port Packet Receive Error
Sense
Key
Sense
Code
Sense
Qualifier
Meaning
Summary of Contents for Atlas 10K V
Page 1: ...Maxtor Atlas 10K V Product Manual September 6 2005 Revision 3 PN 000001911...
Page 39: ...Maxtor Atlas 10K V 3 15...
Page 48: ...3 24 Maxtor Atlas 10K V Figure 3 9 Crosswise Airflow Cooling Below Unit Above Unit...
Page 125: ...Maxtor Atlas 10K V 5 67 21 23 Reserved...