8-Error Listing
The fault alarm points set by the laser include:
SN. Message
Description
Trouble shooting
1
Front lamp
warning
Laser internal
light path testing
fault
Operation leads to low output power
of laser such as low modulation
frequency, low peak power, low
cutting power
2
Pump overheat
warning
Overheat fault of
laser
For the internal overheat fault of
the laser, please check whether
the pre-set temperature of
water-cooling machine meets
the requirements; if this cause
is excluded, please contact
Maxphotonics.
3
Water cooling
plate overheat
warning
Overheat fault
of water cooling
plate
For overheat fault of water cooling
plate, please check whether the
pre-set temperature of water-
cooling machine meets the
requirements
4
Emergency stop
alarm
The emergency
stop switch is
pressed
Release the emergency stop switch,
the laser will work again after being
restarted; if this fault still exists,
please contact Maxphotonics.
5
Water flow error
Pipeline fault of
chiller or laser
Please check whether the water
pressure is normal,the water
pipeline is clear and replace the bad
water switch if need.
6
Overcurrent
warning
Overcurrent fault
of laser
If ''0-10V'' DA value exceeds
the pre-set value, the internal
overcurrent fault will occur; if the
fault is not caused by this reason,
please contact Maxphotonics.