MAXPhotonics MFP-20 User Manual Download Page 13

   

   

MAXPHOTONICS CO.,LTD 

WWW.MAXPHOTONICS.COM 

13

H,  the laser will be out after stated delay. When the level is  L, the laser will be turned 
off after stated delay.

 

 

Notes

 

a. MO should be turned on before 4ms of BS, if not, it will be no laser output. 
b. If turning on the BS first, then the MO

the laser will be out after 1~4ms. The 

above two situation is not list in the manual as they are unusual operation, please try 
to avoid them. BS should be turned on together with the data rising. 
 

7. Pin20 is the input interface of in-phase

The pulse of laser output should be the same 

steps with signal rising  at the stated range ,the pulse repetition rate from this side to input

PRR

)(

referring the limitation of PRR

). 

Notes

if the input PRR above the stated range, the protection system of laser will 

protect the loop and recruit the loss pulse or limitation the data of PRR. 

 

8. 

Pin23 is the input interface of “emergency stop”. When running ok, the level should 

be H, once the level change to L, the laser will be stopped automatically

 the same with 

MO&BS

which  isn’t depend on the other control signal. When restart the laser, please 

make sure that the level of MO &BS should be down to  L 

if the original is H

.If need 

the laser running normally, this signal should be at H level 2

μ

s earlier before offering the 

MO&BS. 

Laser Running 

 

1.Please take off the protecting covering from the laser output head. 

 

2.Please connected the laser mold and control system through DB-25 interface, please 
make reference from the leading of DB25 if necessary  
 
3.Please make sure that the following interface at the initialization rightly 

a)  Pin18

19

22

23 at level L 

 

b)  The Repetition frequency of Pin20 at the stated range 

 

4. Connected the 24VDC power and laser power line

+24V to brown

ground to 

green/yellow

- to blue

 

5. Laser will be running after 120s when gaining the 24VDC power

warming-up time

Notes

it’s allowing to offer the 24VDC main power first

then make the control 

signal initial 

6. Make the emergency stop to

Pin23

H

 

7. Set up the required power through Pin1~8. 

Summary of Contents for MFP-20

Page 1: ...MAXPHOTONICS CO LTD WWW MAXPHOTONICS COM MFP 20 Pulsed Fiber Laser User Manual...

Page 2: ...product Before turn on the power of 220VAC please make sure that the interface is exact otherwise the laser model will be shattered This laser emits more than 20 Watts of invisible laser radiation in...

Page 3: ...MAXPHOTONICS CO LTD WWW MAXPHOTONICS COM 3 Safety Information Safety Conventions This symbol indicates laser radiation We place this symbol on products which have a laser output...

Page 4: ...ication 7 2 Installation 2 1 Installation Measurement Picture 9 2 2 Installation Method 10 3 External Layout 3 1 Interface Specification 11 4 Operation 4 1 Preparation for Use 15 4 2 Operation Steps 1...

Page 5: ...nt in per Watt optical power efficiency as well as low power consumption and practical robust design over traditional diode pumped solid state lasers and is suitable for either laboratory or field ope...

Page 6: ...correct voltage could cause damage to the instrument WARNING No operator serviceable parts inside Refer all servicing to qualified MAXPHOTONICS personnel To prevent electrical shock do not remove cove...

Page 7: ...ge CAUTION In addition to the manual of controls or adjustments or performance other operations may cause the risk of radiation exposure CAUTION It s essential to keep the output lens cleaning After u...

Page 8: ...r Length m 1 9 2 5 3 Output Collimator Bulk Lens Output Beam Diameter 1 e2 mm 6 9 PUMP DIODES Emission Wavelength nm 970 10 Stripe m 1x100 MTTF 20 C hours 30 000 ELECTRICAL CHARACTERISTICS Supplied Vo...

Page 9: ...MAXPHOTONICS CO LTD WWW MAXPHOTONICS COM 9 Humidity 10 to 95 Weight kg 10 2 Installation 2 1 Installation Measurement Picture 2 1 1...

Page 10: ...optics mold That means connecting the cable and radio cable If the single radio cable to the two ends of the molds separately 2 Check that the AC voltage selector 24 set to the correct voltage then pl...

Page 11: ...MAXPHOTONICS CO LTD WWW MAXPHOTONICS COM 11 3 External Layout 3 1 25 pin D shape connector pin assignment...

Page 12: ...in2 0 0 0 0 1 Pin3 0 0 0 0 1 Pin4 0 0 0 0 1 Pin5 0 0 0 1 1 Pin6 0 0 1 1 1 Pin7 0 1 1 1 1 Pin8 1 1 1 1 1 Current 50 75 87 5 93 75 100 The power of the laser 35 65 85 92 100 4 Pin16 and Pin21 are for wa...

Page 13: ...ning ok the level should be H once the level change to L the laser will be stopped automatically the same with MO BS which isn t depend on the other control signal When restart the laser please make s...

Page 14: ...s time The typical time should be 250us the period of modulate should be above 500us the related frequency should be 2kHz 11 After finished a turning on off operation and wait for the next task if the...

Page 15: ...80s warm up time of the marking system otherwise should return on according the order and turn on the computer power at the end 4 2 2 Operation steps of checking laser marking system after turning on...

Page 16: ...defective through normal usage 5 2 Warranty Limitations This warranty excludes products parts including fiber connectors or equipment which have been tampered with opened disassembled opened or modif...

Page 17: ...been noticed and must be directed to MAXPHOTONICS Fiber Laser or its representative in your area Items authorized for return by us must be returned in a suitable container Any damage noted upon recei...

Page 18: ...sured to MAXPHOTONICS FIBER Laser at the address shown herein All products which have returned to MAXPHOTONICS Fiber Laser but which are found to meet all previously applicable specifications for such...

Page 19: ...ccepts a shipment MAXPHOTONICS Fiber Laser will invoice to the Buyer for any charges as stated above 5 Returns for credit will not be accepted unless authorized in advance in writing by MAXPHOTONICS F...

Reviews: