27
Chapter 5 Operation Guide
Pin21 outputs the corresponding alarm signal. If the temperature drops below
+ 45 ° C, the laser will not automatically resume working, and keep the alarm
signal unchanged, restart the operation.
4-Common Boards And Parameter Settings
MFP acousto-optic Q-switched fiber lasers reflect high-speed and high-efficiency
capabilities, so it is required to configure high-speed galvanometers as much as
possible to reflect their performance advantages.
name of
software
SAMlight
NO.
Name / Item
Set parameter value
Typical setting value
unit
1
Empty pen delay
50
~
100
Us
2
Pen delay
50
~
100
Us
3
Turning delay
50
~
100
Us
4
Laser delay
-60
~
-150
Us
5
Laser Delay Off
60
~
150
Us
name of
software
EzCad
(
bjjcz
)
NO.
Name / Item
Set parameter value
Typical setting value
unit
1
End delay
50
~
150
Us
2
Corner delay
50
~
150
Us
3
Laser delay
-50
~
-200
Us
4
Laser Delay Off
20
~
150
Us
5
Laser Delay Off
60
~
150
Us
name of
software
MAX software
NO.
Name / Item
Set parameter value
Typical setting value
unit
1
Empty pen delay
50 ~ 100
Us
2
Marking delay
50 ~ 100
Us
3
Turning delay
20 ~ 100
Us
4
Laser delay
-50 ~ -200
Us
5
Laser Delay Off
50 ~ 150
Us
Recommended Supporting Models For Common Field Lenses
Field
lens focal
length
20X
20W
20H
30X
30W
30H
30H
50X
50W
50H
70W