PLATFORM RAISES PARTIALLY AND STOPS
1.
Lower the opened Platform to the ground. Fill the Reservoir to within 1”
from the top with the recommended Hydraulic Fluid.
2.
Verify that the Battery shows 12 volts or better under load from pump
motor. The use of a voltage load tester is recommended.
3.
Check for Structural damage, or lack of lubrication. Replace worn parts.
4.
Check Filter in the Pump Reservoir. Replace if necessary.
5.
Check for a broken motor-to-pump coupler. Replace if necessary. A worn
pump is extremely noisy, and needs replacement.
6.
If equipped with a Low Voltage Thermal Switch (LVTS), system could
shut down if the motor temperature or battery voltage level reach an
unacceptable level. Read decal P/N 264776 located near the switch to
determine what steps need to be taken to correct the problem.