The PSM must conform to the following electrical characteristics, under all operating conditions, unless 
specifically indicated. 

 

Characteristic 

Performance Criteria 

Conditions 

5V Supply Output 

Max Current: 

1.45 A. 

DC Output: 

4.85 to 5.25V. 

Max Ripple: 

< 100 mV

rms

Efficiency: > 

90% 

All operating temperatures, transmitter 
at full power, external loop active with 
full range of loads. 

-24V Supply 
Output 

Max Current: 

50 mA. 

DC Output: 

-22.0 to -26.0

 

V. 

Max Ripple: 

< 500 mV

rms

Efficiency: > 

90% 

All operating temperatures, transmitter 
at full load, external loop active with full 
range of loads. 

-65V Supply 
Output 

Max Current: 

100 mA. 

DC Output: 

-61.0 to -69.0 V. 

Max Ripple: 

< 500 mV

rms

 

Efficiency: > 

80% 

All operating temperatures, transmitter 
at full load, external loop active with full 
range of loads. 

Power efficiency 
(ac operation) 

Talk Mode: 

> 80% at max output. 

Standby Mode:  > 80% at max output. 

All operating conditions, transmitter at 
full power operation. 

Power efficiency 
(battery operation) 

Talk Mode: 

> 80% at max output. 

Standby Mode:  > 80% at max output. 

All operating conditions, transmitter at 
full power operation. 

 

Table 2.4.2.-1:  Primary PSU Electrical Characteristics. 

2.5. 

Battery Management Module (BMM). 

 

The Battery Management Module (BMM) manages the distribution and source for the LAUs primary 
power sources, battery and ac power.  As such, it provides the following basic functions: 

 

• 

Monitors the status of the input ac power signal, and controls the switch-over between ac power 
and battery reserve power when ac power failure occurs.

 

• 

Measures the charge level of the reserve battery, and controls the charging input to the battery 
according to the discharge level, battery temperature, and ambient temperature conditions.

 

• 

Generates necessary power-on reset signals to other modules within the LAU, assuring proper 
initialization when power is applied.

 

• 

Provides output indications of certain power-related fault conditions.

 

2.5.1. Functional 

Characteristics. 

 

These are the functional requirements for the Battery Management Module. 

 

Characteristic 

Performance Criteria 

Battery / AC Power Source Selection 

The BMM controls the source of electrical power for 
the LAU by monitoring the ac power input and the dc 
battery level.  The following criteria determine which 
source provides the operating power for the LAU 
circuitry: 
 

• 

If AC power is present on the 19 VOLTS IN line, 
then battery supply power is turned of. 

If Battery power is present and AC power is not, 

Summary of Contents for J-STD-008

Page 1: ...ns technical data and or inventions which are the proprietary rights of Maxon America Inc and are disclosed in confidence to the recipient of this print for use by the recipient only in considering or...

Page 2: ...PS SAU 1900E Mar 8th 1999 Rev 0 0 CONFIDENTIAL AND PROPRIETARY 2 Table of Revisions Date Revision Changes Mar 8th 1999 0 0 1 First draft release...

Page 3: ...stics 20 2 7 Analog Fax Module Interface AFMI 21 2 7 2 Functional Characteristics 21 3 Software Description 21 3 1 Telephone Interface 21 3 1 1 Telephone Interface State Diagram 22 3 1 2 INCOMING CALL...

Page 4: ...TIAL AND PROPRIETARY 4 3 3 1 2 Configuration Requirements for J STD 008 System Interface 34 3 3 1 3 LAU Application Specific Hardware Configuration Requirements 35 3 3 2 Product Test and Maintenance 3...

Page 5: ...Y time when measured from a condition of full charge at an ambient temperature of 25 C Battery Recharge Time The recharge system will provide sufficient capability to fully recharge the reserve batter...

Page 6: ...r Antenna remote To be defined after further field evaluation Indicators One 1 LED In Service Shows No PILOT Channel LED off Marginal PILOT Channel LED blink Good PILOT Channel LED on The Frame Error...

Page 7: ...te after the following sources are connected to the tip and ring pins of the RJ 11 output for up to 5 minutes regardless of polarity DC 56 Vdc through 400 AC 56 Vdc with 90 Vrms superimposed through 4...

Page 8: ...r J STD 008 Mobile Station Base Station Compatibility Standard for 1 8 to 2 0GHz Code Division Multiple Access Personal Communications System Vocoder Requirements 8 kbps CELP and 13 kbps QCELP EVRC as...

Page 9: ...ices will be through the product s RJ 11 interface adapters A special interface cable converter may be required to connect the analog device to the product The electrical characteristics of this inter...

Page 10: ...dc Talk battery 24 Vdc Logic supply 5 Vdc Status indicators CDMA Module Digital circuits MSM controller BBA interface Program memory Data memory Configuration memory Serial I O Line Interface Module p...

Page 11: ...input from ac dc converter transformer Service 3 Two wire serial I O interface with ground reference pin Serial data is output as a unipolar TTL level signal referenced to the LAU s internal ground Ma...

Page 12: ...ook detected assuming Network Accessed Tnetwork_Accessed 20 ms t 300 ms NOTE The value Tnetwork_Accessed is system dependent The product continuously verifies network access conditions when powered If...

Page 13: ...lot and Sync channel Also applied during certain situations to warn the user of improper operating conditions on the LAU Telephone interface dialing time outs etc Busy Tone This tone should be support...

Page 14: ...1 0 2 0 Four 4 REN 1 75 K PBX Key System Support There is no current requirement for the LAU to interface with PBX or key system trunk cards It is desirable but not required for the product to interf...

Page 15: ...requency Response 300 3300 Hz 3 dB Audio Path Distortion Limits TX System must accurately decode all DTMF digits when signals are applied to input at maximum allowed levels RX Assuming a network signa...

Page 16: ...Lines and Terminal Equipment reference document Defines operation of North American Public Telephone Network analog interface EIA TIA 571 1996 Environmental Considerations for Telephone Terminals TIA...

Page 17: ...n Table 2 4 2 1 Primary PSU Electrical Characteristics 2 5 Battery Management Module BMM The Battery Management Module BMM manages the distribution and source for the LAUs primary power sources batter...

Page 18: ...with 0 026V C of slope 2 6 CDMA Module CDM The CDM provides the CDMA RF interface between the outside world and the CDMA modulated IF data signals originating or terminating on the Base Band circuit...

Page 19: ...line used to detect Valid DTMF signal 1 Invalid 0 Valid 15 U20_X2 MAIN_TEMP A D input for Main board battery temperature sensor 16 KEYSENSE2 DTMF_D1 Keysense2 line used to detect DTMF digit in conjun...

Page 20: ...string Data levels are 3 3 volt ground referenced unipolar digital signals Maximum data rates are 115 2 kbaud 41 RFR RFR Ready to Send Line 42 DP_TX_DATA MSM_TXD Serial port transmitted data string D...

Page 21: ...Module This module is a real time multi tasking software package provided by Qualcomm and designed to run specifically with the Qualcomm Mobile Station Modem MSM and Base Band ASIC BBA system ICs This...

Page 22: ...unit reads in E2PROM configuration data and then performs various operations necessary to set up the LAU s hardware interfaces ACQUIRE SYSTEM State This state is actually a major state within the Qual...

Page 23: ...itch transition is detected on the analog telephone interface The LAU then initiates the necessary control sequence to receive dialed digits seize an RF channel and place the call If an incoming call...

Page 24: ...eatment and Caller ID Data Transmission The LAU enters this substate when an ALERT indication has been detected The LAU now determines which type of ring treatment is to be applied over the analog int...

Page 25: ...so contains the calling party number information The LAU is then able to build an appropriate CLID message by drawing the calling number information from the Alert message and the date time informatio...

Page 26: ...til an On Hook condition is detected or until the Receiver On Hook timer expires 3 1 3 3 Gather Dialed Digits Substate The LAU begins gathering digits immediately upon detection of the first DTMF inpu...

Page 27: ...l accept the button in either the third or fourth digit position and register it as part of the dial string A subsequent occurrence of the button will cause SEND to occur depending on configuration of...

Page 28: ...erface This flash is detected by the LAU which then transmits a FLASH_WITH_INFORMATION message to the B S The B S places the current call on hold then connects the incoming call The LAU user returns t...

Page 29: ...re situation as follows 1 The incoming call will cause the LAU to apply a Call Waiting tone to the analog loop interface 2 When the Call Waiting tone is received by the user two options exist In the f...

Page 30: ...Power Scan 0 X 0 1 Forward Disconnect 1 X 1 0 Ring State Values in italics are initial conditions at power up The SLIC is initialized to Low Power Scan at unit power up When the phone is on hook in t...

Page 31: ...2 2 Power Supply Module The power supply board has two control inputs as shown below Control Signal State Function DCDC_0 0 Power Supply is OFF 1 Power Supply is ON 65 24Vdc Power Supply ON OFF contr...

Page 32: ...he battery voltage monitoring state The software monitors the battery voltage through the output V_BATT If the V_BATT reading from the ADC drops below the minimum set point for more than one second th...

Page 33: ...s six 6 inputs from CDMA Module Battery management Module PA_TEMP PA_DET AC_POWER MAIN_TEMP V_BATT Vref 2 084Volts The MUX is initialized to select X4 which a reference voltage to calibrate A D conver...

Page 34: ...re package which guides the user through the various product configuration options and provides the necessary LAU programming control 3 3 1 2 Configuration Requirements for J STD 008 System Interface...

Page 35: ...parameter NAM name Directory Number Access Overload Class CDMA Phone Number Mobile Country Code Mobile Network Code CDMA Primary Channel A CDMA Primary Channel B CDMA Secondary Channel A CDMA Secondar...

Page 36: ...part of the dial sequence and will not treat it as a SEND command The next occurrence of the button will cause a SEND If DISABLED then any occurrence of the button after the first digit will cause a...

Page 37: ...ace enters the OFF HOOK condition in response to user s intent to place an outgoing call Terminated upon receipt of first dialed digit Frequency 1 Frequency 2 Amplitude Factory Yes Field Yes End User...

Page 38: ...l Frequency 1 Frequency 2 Amplitude Numbers of beeps Factory Yes Field Yes End User No Dialed Digits Manual Send ENABLE_PND_KEY When enabled forces the user to press the button to send gathered digits...

Page 39: ...ew LAU operating software 4 Replaceable and Optional Components The following components will be replaceable items Battery Sealed lead acid 12 V 2 Ahr Yuasa NP2 12 or equivalent Transformer Market spe...

Reviews: