PS-SAU-1900E
Mar. 8
th
,1999 (Rev. 0.0)
--- CONFIDENTIAL AND PROPRIETARY ---
37
“#” will always be part of
the dial sequence if it
occurs in the first digit
position.
The “#” as SEND option
can be enabled or
disabled, subject to the
rules of that feature.
VOC RX Gain
(VOC_INDEX)
CODEC gain in received
voice path.
•
Gain level.
•
Factory Yes
•
Field Yes
•
End User No
Auto Send enable
(DDT_BYPASS)
When enabled, causes
the LAU to automatically
transmit all gathered digits
to the B/S at a
programmable time after
the last detected digit is
received. Dialed Digits
Manual Send may be
enabled concurrent to this
feature.
•
Feature ON/OFF.
•
Factory Yes
•
Field Yes
•
End User No
Dial
Tone
(DIAL_TONE)
Applied to the analog loop
audio path by the LAU
when the loop interface
enters the OFF HOOK
condition, in response to
user’s intent to place an
outgoing call. Terminated
upon receipt of first dialed
digit.
•
Frequency 1
•
Frequency 2
•
Amplitude
•
Factory Yes
•
Field Yes
•
End User No
Reorder
Tone
(REORDER_TONE)
Applied to the analog loop
audio path by the LAU
when the CDMA system
cannot be accessed.
•
Frequency 1
•
Frequency 2
•
Amplitude
•
Factory Yes
•
Field Yes
•
End User No
Receiver Off Hook
Tone
(ROH_TONE)
Applied to the analog loop
audio path by the LAU
when the external loop
has been in the off hook
condition with no call in
progress for a period of
time.
•
Frequency 1
•
Frequency 2
•
Amplitude
•
Duration
•
Delay to Start
•
Factory Yes
•
Field Yes
•
End User No
Custom Recall Tone
(RECALL_TONE)
Custom recall tone.
Currently not used on
SAU-1900E
•
•
Marginal Pilot
threshold
(MARGINAL_PILOT)
Set marginal pilot
threshold point so LAU
can blink signal led when
receive weak signal)
•
Threshold
•
Factory Yes
•
Field
Yes
•