You have decided to purchase a top Slidelift. The Maxon Slidelift is very easy to use and to 

maintain. It is equipped with maintenance and grease-free bearings, and does not require greasing 

throughout its entire lifetime. The Maxon Slidelift is only to be used for lifting and lowering of loads, 

which have to be placed on the platform in accordance with the loading diagram. 

The Slidelift must only be operated, maintained and repaired by persons who have been 

technically trained and who have especially been informed about the hazards that may occur 

during operation. Otherwise, manufacturer's liability for resulting damages is void.

These operating instructions are valid for following lifts: 

Daily verifications : 

1.  Function and completeness of all operating and security equipment 
2.  Legibility of all operating and information labels (replace if necessary) 
3.  Damages and completeness on bolts, bolt retainers, cracked or broken bolts and nuts 
4.  Damages and tightness of hoses, fittings and valves on hydraulic cylinders. Check all 

hoses for leaks and tightness 

5.  Verify deformation of under ride device and energy absorber 
6.  Damages and function of platform warning lights 
7.  The function of the battery main switch (option) is to be checked 

Recommended checks every month: 

1.  Check hydraulic fittings for tightness and tightening torque. 
2.  Check oil level. 

If necessary correct with recommended oil. 

3.  Check wires and cables for damages. 

Replace missing cable fasteners. 

            Correct if there are cutting and shearing risks. 

4.  Check hydraulic hoses for damages. 

Replace missing  fasteners. 

Correct if there are cutting and shearing risks. 

5.  Check that al decals are in place and full readable. 

Replace missing or damaged decals. 

6.  Check rubber seals at bearings. 

Replace missing or damaged seals. 

7.  Check that all bearing pins are secured and without damage. 

Model 

GPS 44X1 

GPS 55X1 

Capacity 

4,400 lbs 

5,500 lbs 

Summary of Contents for 55X1

Page 1: ...www frimax mx MANUAL DE USUARIO Serie Deslizables GPS...

Page 2: ...P g 8 P g 1 P g 5 Informaci n general Carga del cami n Recomendaciones Desplazamiento P g 4 Controles de mano Aseguraci n de carga Reparaci n de elementos de rodamiento P g 10 Trasnsferencia de carga...

Page 3: ...ent 2 Legibility of all operating and information labels replace if necessary 3 Damages and completeness on bolts bolt retainers cracked or broken bolts and nuts 4 Damages and tightness of hoses fitti...

Page 4: ...ks or deformation Any failure must be repaired immediately and any missing part is to be replaced at once The vehicle operator is responsible for repairs in due time of known damages The operating ins...

Page 5: ...ox Using the control box both hands must be used to operate control box Foot Controls The foot controls are connected so that they only work when pushed in a specific order To lift and tilt up Step 1...

Page 6: ...ore the lift stops immediately Pressure relief valve The lift is secured against the lifting of loads which are heavier than its capacity by an overload security valve set at the factory An adjustment...

Page 7: ...lideframe and platform Riding on the platform When loading the platform please leave enough space to ensure that the operator can ride and operate the platform safely The handle optional must be withi...

Page 8: ...equest Maxon Slidelifts can be equipped with cart stops securing rolling loads with the maximum efficiency wheels with maximum diameter 4 Security instructions when operating the Slidelift Caution at...

Page 9: ...tification plate The load s centre of gravity should be in the middle between the lift arms The greater the distance of the load from the end of the flatbed the lower the loading capacity The maximum...

Page 10: ...e heavier than its rated capacity nor against loads which are brought onto the platform at the wrong loading distance An overload can lead to heavy damage breaking of the platform The operator is resp...

Page 11: ...Slidelift is retractet under the vehicle Despite the kind of loading performed the vehicle has to be secured against unintentional movement use hand breakes or wedges Loading and unloading at a dock...

Page 12: ...areas should not be cleaned with high pressure or steam jets as this may allow dirt and moisture to penetrate into the bearing Check all hydraulics for leaks With the Slidelift platform completely lo...

Page 13: ...l e r r e w o p e h T e v i t c e f e d r o t o M 2 Motor does not work on one function only Toggleswitch on hand control box defective e v i t c e f e d x o b p m u p o t x o b l o r t n o c d n a h...

Page 14: ...d loading distance h g i h o o t d a o l f o t h g i e W y l r e p o r p t e s t o n e v l a v y t i r u c e s d a o l r e v O Pump defective y r e t t a B w o l t n e i c i f f u s n i e g a t l o V...

Page 15: ...t of service dealers on request Contact Maxon Technical Service at 1 800 227 4116 or fax 888 771 7713 Warranty MAXON LIFT CORP 11921 Slauson Ave Santa Fe Springs CA 90670 CUSTOMER SERVICE 562 464 0099...

Page 16: ...the return of any defective part Defective Parts must be returned within 60 days of the claim date for consideration to Warranty Dapartment MAXON Lift Corp 5920 Alameda St Huntington Park CA 90255 Max...

Page 17: ...VENT www SERVICIO T CNICO MANUFACTURA FRIO VAN AS GARANT A servicio t cnico partes frimax mx...

Reviews: