maxon motor control
7
maxon motor
Operating Instructions
1-Q-EC Amplifier DEC Module 24/2
April 2015 Edition / document number 1002422_PDF_E - 04 / subject to change
5 Functional Description of Inputs and Outputs
5.1 Inputs
5.1.1 Speed range and mode selection with «DigIN1» und «DigIN2»
The digital inputs «DigIN1» [11] and «DigIN2» [12] determine both, the ope-
ration mode (digital speed controller or digital speed actuator) and the speed
range in speed set value mode.
Motor type
DigIN1 DigIN2
1 pole pair
4 pole pair
8 pole pair
0
0
Open loop speed control, 0...100 % PWM
depending on the «Set value speed» input voltage
1
0
500...5 000 rpm
125...1 250 rpm
62...625 rpm
0
1
500...20 000 rpm
125... 5 000 rpm
62...2 500 rpm
1
1
500...80 000 rpm
125...20 000 rpm
62...10 000 rpm
Please note
Ö
If the signal level of the digital inputs DigIN1 [
11
] and DigIN2 [
12
] are
changed, the new levels are adopted by a disable-enable procedure.
If the input «DigIN» is not connected (floating) or a voltage higher than 2.4 V
is applied, the input is active.
Logic 1
Input not connected (floating)
Input voltage > 2.4 V
Input active
If the input «DigIN» is set to ground potential or a voltage smaller than 0.8 V
is applied, the digital input is inactive
Logic 0
Input set to Gnd
Input voltage < 0.8 V
Input inactive
The inputs «DigIN1»and «DigIN2» are protected against over voltage.
Digital input 1
Pin number [11] «DigIN1»
Digital input 2
Pin number [12] «DigIN2»
Input voltage range
0 ... +5 V
Input impedance
15 k
Ω
pull-up resistor against 5 V
Continuous over voltage protection
-28 ... +28 V