General Wiring Diagram
CAUTION:
Turn off electrical power at
fuse or circuit breaker box before wiring
fixture to the power supply.
Connecting panels to AC source supply:
All units must be individually connected to
the AC supply.
Black = Line
White = Neutral
Green = Ground
Installation & Operation - Junction Box Mounting:
1.
Unscrew the screws on the right side using a
suitable screwdriver. Separate the male and
female connectors, then remove the reflector
from the back plate.
2.
Create four 5.0mm holes by knocking-out the four points indicated
in A/B/C/D. Unscrew Bolt(1) from the bottom center. (Note: the
other three Bolts (2)/(3)/(4) can be unscrewed depending on
your requirements during the wiring process.)
3.
Run the main power wire from the water-proof
J-box through the hole(H), then lock the back
plate to the water-proof J-box using four
#8-32 screws.
4.
Use the hinge to lock the reflector to the back plate firmly, then
connect the main power. Black wiring to L, White to N, Green
to G (see diagram above.) Next, connect the male and female
connectors together. Finally, use a suitable screwdriver to
connect the reflector to the back plate.
© Copyright 2018. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006 Tel: 800-555-5629 Fax: 973-244-7333 Email: [email protected]
Page: 2
REV: 8/28/18
(+)
LINE
(-)
COMMON
GROUND
GREEN
WHITE
BLACK
Light
Fixture
Reflector
Male
Connector
Female
Connector
Bolt (4)
Bolt (3)
Bolt (2)
Bolt (1)
Back Plate
Electric
Drill
#8-32 Screws Main Power
Hole(H)
Water-proof J-Box
Reflector
Male
Connector
Female
Connector
Back Plate
A
D
C
B
Operating Instructions WP-OP Series
MaxLite WallMax™ Open Face
®