background image

The MAXIMUM

®

 Air-powered Brad Nailer

has a depth adjustment dial below the trigger

to adjust the firing depth of the fasteners.

Note: Refer to the graphic imprinted below

the trigger and adjust the firing depth

accordingly (Fig. F).

The MAXIMUM

®

 Air-powered Brad Nailer is equipped with a single sequential 

actuation mode.
1. Press the safety stand against the workpiece.

2. Pull the trigger in order to drive the nail with the safety tip pressed firmly 

    against the workpiece.

3. If the safety stand remains pressed, successive nails will fire each time the 

    trigger is pulled.

5. Test the driving depth of the tool against
    a scrap piece of wood by pressing the
    trigger (1) before working on the
    workpiece. If the nails are being driven
    too deep or not deep enough, adjust the
    regulator in the air supply in order to
    provide more or less air pressure, as
    required (Fig. E).

CAUTION!

Potential hazard that may result in injury or damage to 
equipment.

• Operate the tool with the utmost care when it is connected 

   to the air compressor. Failure to comply may result in 
   injury or damage to equipment.

17

16

model no. 058-9340-0 |  contact us 1-888-670-6682

WARNING!

Potential hazard that could result in serious injury or

 loss of life.

• The safety stand must be in contact with the workpiece 

   before activating the tool.

• Do not operate the tool if the nails are not loaded, as doing 

   so may damage the tool.

• Do not fire nails into the air, as doing so may cause injury 

   to the operators or others, apart from damaging the tool.

• Do not load different sized nails into the magazine, as doing 

   so may cause nails to jam. Failure to comply could lead to
   serious injury or loss of life.

CAUTION!

Potential hazard that may result in injury or damage to 

equipment.

• If the trigger is pressed a second time, the recoil of the 

   nailer may lift the safety stand enough to allow a second 

   nail to be fired, even if the operator has not lifted the tip 

   of the safety stand.

• Operate the tool with the utmost care when it is connected 

   with the air compressor. Failure to comply may result in 
   injury or damage to equipment.

4. Plug in compressor, turn it on, set the
    pressure regulator to 90 PSI, and attach 
    one end of the air hose to the compressor
    and the other end of the air hose (1) to
    the tool (2). Use plumber’s tape to
    prevent air leaks (Fig. D). 

Fasteners depth adjustment

DECREASING FASTENER DEPTH INCREASING FASTENER DEPTH

Turn the depth adjustment dial
counterclockwise (with the 
discharge area of the tool facing 
away from the operator and other 
people) (Fig. G).

Turn the depth adjustment dial 
clockwise (with the discharge area 
of the tool facing away from the 
operator and other people) (Fig. H).

Firing modes

1

Fig. E

1

2

Fig. D

Fig. F

Fig. G

Fig. H

TM

Summary of Contents for 058-9340-0

Page 1: ...Air powered Brad Nailer INSTRUCTION MANUAL IMPORTANT Please read this manual carefully before using this product and save it for reference Model No 058 9340 0...

Page 2: ...ll our toll free helpline at 1 888 670 6682 4 5 10 11 14 15 19 20 22 23 24 TABLE OF CONTENTS TECHNICAL SPECIFICATIONS SAFETY GUIDELINES KEY PARTS DIAGRAM TECHNICAL INFORMATION TYPES OF NAILS OPERATING...

Page 3: ...ains information that relates to PROTECTING PERSONAL SAFETY and PREVENTING EQUIPMENT PROBLEMS It is very important to read this manual carefully and understand it thoroughly before using the product T...

Page 4: ...piece or by objects in the workpiece or if they are driven away from the point of entry Do not drive a nail on top of existing nails The nail may ricochet causing serious personal injury Use only nail...

Page 5: ...clear and clean This tool is not a toy Use it with caution Handling and storage of oil Use the tool with adequate ventilation Avoid contact of oil with eyes skin and clothing Avoid breathing spray or...

Page 6: ...compressor with MAXIMUM Air powered tools The compressor that is being used must be able to supply appropriate amount of pressure PSI to the tool 11 10 model no 058 9340 0 contact us 1 888 670 6682 N...

Page 7: ...per working order Do not use oxygen or any other combustible or bottled gas to power this tool Do not use this tool in the presence of any ammable liquids or gases Keep hands and other parts of the bo...

Page 8: ...er to the actual tool for the speci c colour 2 Hold the Air powered Brad Nailer rmly with one hand Use the other hand to press the latch 1 on the magazine 2 and slide it back Fig B 1 Disconnect the to...

Page 9: ...ith the workpiece before activating the tool Do not operate the tool if the nails are not loaded as doing so may damage the tool Do not re nails into the air as doing so may cause injury to the operat...

Page 10: ...e tool as described in the maintenance section Drain the compressor tanks at least once per day Clearing a jammed nail To clear a jammed nail Disconnect the tool from the air supply line Remove the na...

Page 11: ...in the trigger valve are damaged The trigger valve heads are damaged Trigger valve stem seal or O rings are damaged 1 2 3 The air supply is inadequate Lubrication is inadequate The O rings or seals ar...

Page 12: ...ng B Adjustable nut II Retainer Adjustable stem Safety guide Guide sleeve Bolt M3 x 8 Adjustable bolt O ring 7 x 1 5 Valve bush Screw spring O ring 1 9 x 1 1 Switch lever O ring 11 2 x 1 6 Trigger val...

Page 13: ...e damage is caused by repairs made or attempted by others i e persons not authorized by the manufacturer and any such unauthorized repairs or attempted repairs shall void this warranty in its entirety...

Page 14: ...nding any provision herein or entitlement of the purchaser at law in equity or otherwise in no event shall the liability of the retailer or manufacturer under this warranty whether in contract tort pr...

Reviews: