The MAXIMUM
®
Air-powered Brad Nailer
has a depth adjustment dial below the trigger
to adjust the firing depth of the fasteners.
Note: Refer to the graphic imprinted below
the trigger and adjust the firing depth
accordingly (Fig. F).
The MAXIMUM
®
Air-powered Brad Nailer is equipped with a single sequential
actuation mode.
1. Press the safety stand against the workpiece.
2. Pull the trigger in order to drive the nail with the safety tip pressed firmly
against the workpiece.
3. If the safety stand remains pressed, successive nails will fire each time the
trigger is pulled.
5. Test the driving depth of the tool against
a scrap piece of wood by pressing the
trigger (1) before working on the
workpiece. If the nails are being driven
too deep or not deep enough, adjust the
regulator in the air supply in order to
provide more or less air pressure, as
required (Fig. E).
CAUTION!
Potential hazard that may result in injury or damage to
equipment.
• Operate the tool with the utmost care when it is connected
to the air compressor. Failure to comply may result in
injury or damage to equipment.
17
16
model no. 058-9340-0 | contact us 1-888-670-6682
WARNING!
Potential hazard that could result in serious injury or
loss of life.
• The safety stand must be in contact with the workpiece
before activating the tool.
• Do not operate the tool if the nails are not loaded, as doing
so may damage the tool.
• Do not fire nails into the air, as doing so may cause injury
to the operators or others, apart from damaging the tool.
• Do not load different sized nails into the magazine, as doing
so may cause nails to jam. Failure to comply could lead to
serious injury or loss of life.
CAUTION!
Potential hazard that may result in injury or damage to
equipment.
• If the trigger is pressed a second time, the recoil of the
nailer may lift the safety stand enough to allow a second
nail to be fired, even if the operator has not lifted the tip
of the safety stand.
• Operate the tool with the utmost care when it is connected
with the air compressor. Failure to comply may result in
injury or damage to equipment.
4. Plug in compressor, turn it on, set the
pressure regulator to 90 PSI, and attach
one end of the air hose to the compressor
and the other end of the air hose (1) to
the tool (2). Use plumber’s tape to
prevent air leaks (Fig. D).
Fasteners depth adjustment
DECREASING FASTENER DEPTH INCREASING FASTENER DEPTH
Turn the depth adjustment dial
counterclockwise (with the
discharge area of the tool facing
away from the operator and other
people) (Fig. G).
Turn the depth adjustment dial
clockwise (with the discharge area
of the tool facing away from the
operator and other people) (Fig. H).
Firing modes
1
Fig. E
1
2
Fig. D
Fig. F
Fig. G
Fig. H
TM