Maximum Controls MAX SUPER ARM 2300 Installation And Owner'S Manual Download Page 19

17

MAX Super 1300/2300 Arms V1C

Minimum distance

needed for clearance

See page 24 for

PULL OPEN

installation steps.

See page 25 for

PUSH OPEN

installation steps.

Table in inches

2300 pull open dimensions

2300 push open dimensions

C

C

C1

C1

C1

Operator protrudes 

roughly 10”

 inside driveway area reducing driveway width.

54.72” Max

DO NOT

 Fully

Extend Drive Rod

54.72” Max

DO NOT

 Fully

Extend Drive Rod

19.88” Max

1.5”

1.5”

19.88” Max

2.16” Min

Minimum

3.93”

Recommended

6”

Minimum 6.29”

Y

X

Obstructed

Area

C1

2.16” Min

12”

8ft

2.4 m

12ft

3.6 m

16ft

4.8 m

20ft

6.0 m

Max Gate

Weight/Length

2300 lbs

1043 kg

2000 lbs

907 kg

1800 lbs

816 kg

1500 lbs

680 kg

D

NOTE for Bi-parting gates 

using overlap/maglock:

Motor 1/Primary gate opens 

FIRST

. Install overlap/maglock 

accordingly to account for this.

A

B

A

5.51”

6.29”

7”

7.87”

8.66”

9.44”

B

C / C1

49.8/15.0 50.9/16.2 52.2/17.7 54.0/19.3 54.5/19.7 54.2/19.4

55/20.2

54/19.3

53.1/18.4 54.3/19.6 54.7/19.6

54.5/19.8

52.3/17.5 53.5/18.8 54.7/19.9

54.5/19.7

51.4/16.6 52.7/17.9 54.0/19.2 54.5/19.7

54.5/19.7

50.6/15.9 51.8/17.0 53.3/18.5 54.4/19.6 54.1/19.4

7”

91°

95°

102°

108°

103°

96°

7.87”

91°

95°

101°

103°

95°

93°

8.66”

90°

95°

100°

97°

92°

9.44”

90°

95°

98°

91°

10.23”

90°

94°

91°

11”

90°

11.8”

90°

Max. gate width

per gate

157.4”

177.2”

196.8”

 max super arm 2300

Recommended 10”

Rev 06-21-22

STR

ONGE

R

FA

ST

ER

Summary of Contents for MAX SUPER ARM 2300

Page 1: ...ASS I II III IV CERTIFIED TO CAN CSA STD C22 2 NO 247 SAFETY SENSORS REQUIRED JO G GATE OPEN CLO SE RESET ALA RM M a x C o n t r o l B o x Installation and Owners manual for max super arm 1300 max sup...

Page 2: ......

Page 3: ...e Gate Miller R Band Wireless iGaze RE Kit Wireless 43 44 45 46 47 48 49 50 51 gate safety and requirements Important Gate Construction Information General Requirements UL 325 Compliant Installation R...

Page 4: ...tery back up cycles 7 Amp Hr batteries fully charged Approx 500 cycles Entrapment protection UL 325 Type A Inherent ERD sensor Inputs for NORMALLY CLOSED N C or 10K Type UL 325 Type B1 photo cell and...

Page 5: ...31 F to 158 F 25 C 70 C 9 25 235 mm Max 54 75 1391 mm 8ft 2 4 m 12ft 3 6 m 16ft 4 8 m 20ft 6 0 m Max Gate Weight Length 2300 lbs 1043 kg 2000 lbs 907 kg 1800 lbs 816 kg 1500 lbs 680 kg max super arm 1...

Page 6: ...or less above grade shall be guarded or covered All openings shall be designed guarded or screened from the bottom of the gate to the top of the gate or a minimum of 72 in 1 83 m above grade whichever...

Page 7: ...fermeture la barri re doit tre install e dans un endroit o la barri re et les structures avoisinantes sont suffisamment loign es l une de l autre Les barriers battantes ne doivent pas ouvrir dans une...

Page 8: ...ct doit tre situ o il existe un risque de coincement ou d obstruction comme sur le bord d ouverture sur le bord de fermeture et sur les poteaux mont s sur l int rieur ou l ext rieur d une barri re cou...

Page 9: ...y can increase the risk of injury or death 4 V rifiez le fonctionnement de l ouvre barri re une fois par mois Le sens de la course DOIT s inverser lorsque la barri re entre en contact avec un objet du...

Page 10: ...by security personnel SECURITY AUTHORIZED PERSONNEL ONLY ul 325 model classifications A Inherent entrapment protection system B1 Provision for connection of a non contact sensor photoelectric sensor o...

Page 11: ...ceeding 0 50 inches If distance is greater than 4 inches for this area then entrapment protection is required If distance is less than 16 inches entrapment protection is required in this area With the...

Page 12: ...S shall be installed One on EACH side of the gate area where easily visible Moving Gate Can Cause Serious Injury or Death KEEP CLEAR Gate may move at any time without prior warning Do not let children...

Page 13: ...e is for ve hic les on ly Pe de str ian s mus t us e se pa rate en tra nc e M ovin g Gate Can Cause Serious In ju ry or Death KE EP CL EA R Ga te may mov e at an y tim e withou t prior wa rning Do no...

Page 14: ...1300 max super arm 2300 Page 12 14 Page 15 17 1a mount Super arm 1300 Front Bracket Bolt or weld to gate Mounting Hardware Not Supplied Mounting Hardware Not Supplied Locknut Bolt 1300 brackets Lift...

Page 15: ...brackets making sure that arm is LEVEL Temporarily Mount Arm If brackets are going to be welded to the gate and or wall only tack weld the brackets with the arm attached Protect the arm from welding...

Page 16: ...1 9 17 5 40 3 15 9 51 4 17 0 52 2 17 7 52 9 18 5 53 8 19 4 54 6 20 1 53 5 19 1 52 7 18 3 54 3 19 9 55 4 21 0 56 3 21 9 56 6 22 2 56 8 22 4 55 2 20 8 56 2 21 8 57 0 22 5 56 9 22 5 56 1 21 6 57 0 22 5 5...

Page 17: ...e Locknut Bolt Sleeve Anchors Not Supplied Drive Rod PULL Open Rear Bracket PUSH Open Rear Bracket 1 2 See page 17 for bracket positions and dimensions Weld completely around the bracket to secure to...

Page 18: ...t of this manual pages 4 11 for mounting requirements and limitations Drive Rod Extension Temporarily mount arm in desired position determined by next page s dimensions Manually swing gate to the OPEN...

Page 19: ...m Max Gate Weight Length 2300 lbs 1043 kg 2000 lbs 907 kg 1800 lbs 816 kg 1500 lbs 680 kg D NOTE for Bi parting gates using overlap maglock Motor 1 Primary gate opens FIRST Install overlap maglock ac...

Page 20: ...help with re installation Couplings and conduit not provided Use flexible conduit to connect to control box not provided EXIT PWR ALARM POWER SOLAR IN BATTERY INPUT OPENING CLOSING MOTOR 2 MOTOR 1 ERD...

Page 21: ...V Single Phase 230VAC Only 230VAC 230V Set to 230V Power Terminal IMPORTANT Make sure there are NO exposed bare wires at the power terminal connection 115 OR 230VAC Input AC Power Wire CAUTION Make su...

Page 22: ...nt for LIGHTNING PROTECTION in lightning prone areas To be effective ground connections should be made with a minimum 12 AWG 600 volt insulated wire to a ground point within 10 feet of the control box...

Page 23: ...E ON M 3 1 TROL SE L CLOSING MAX NSE B BACK ENSITIVITY PLACE TTERY LEAV CLOSE LEAVE OPEN Y VOLTAGE F 2 16 MIN 3 1 14 7 M CONTRO ONTROL LOOP PWR D GNAL 2VDC OUTPUT GND Gate Set the desired opening dire...

Page 24: ...PEN position 1 Clear limits from control box memory Press and HOLD STOP and CLOSE buttons together for 5 sec until BEEP ALARM is heard Screen will display LEARNING LIMITS 10 Manually move gate to CLOS...

Page 25: ...xtend shaft to 3 1 4 typical as shown This will be CLOSE position of operator 6 Bolt FRONT bracket to operator 7 Manually move gate to CLOSE position 1 Clear limits from control box memory Press and H...

Page 26: ...ate to OPEN position 1 Clear limits from control box memory Press and HOLD STOP and CLOSE buttons together for 5 sec until BEEP ALARM is heard Screen will display LEARNING LIMITS 10 Manually move gate...

Page 27: ...heard from control box 5 Extend shaft to 3 1 4 typical as shown This will be CLOSE position of operator 6 Bolt FRONT bracket to operator 7 Manually move gate to CLOSE position 1 Clear limits from cont...

Page 28: ...Closing ONLY 10K N C Sensing Edge WIRELESS NOTE Refer to the instruction sheet that comes with the wireless module for wiring and mounting instructions when using wireless option Top View Side View Se...

Page 29: ...ut factory default Power Power test photo cls nc sensor Test PHOTO CLS NC entrapment protection sensor Photocell typically used 1 Press and HOLD the STOP button then the OPEN button together until bee...

Page 30: ...7 MOTION CONTROL OPEN STOP CLOSE Adjust ERD for EACH direction In Ground Loops Loop Detector Rack Safety loops wired in series Center Loop Safety Loop Safety Loop Exit Loop Plug In Loop Detectors EDI...

Page 31: ...Arm Ultra Arm EXIT PWR ALARM POWER SOLAR IN BATTERY INPUT OPENING CLOSING MOTOR 2 MOTOR 1 ERD OBD PORT BLACK BOX PROGRAMMING SOLAR MODE MOTOR OVER LOAD ERD MOTOR OVER LOAD MIN MAX OFF MAX SENSE MAX S...

Page 32: ...C OPEN CLS NC GND 12VDC OUT GND CLS ONLY 10K OPEN CLS 10K 12VDC OUT UL SENSOR N C UL SENSOR 10K O R N C O R N C O R N C O R N C O N C N C N C N C C SENSOR SENSO SENSO SENSO SENSO ENSO ENS ENS NS O R 1...

Page 33: ...SE RES ET ALA RM dual gate operators OPERATOR switch MUST be set to DUAL Jog OPEN CLOSE buttons operate BOTH arms together EACH arm is MANUALLY RELEASED individually CLOSING GATE SPEED is adjusted for...

Page 34: ...MIT 2 LIMIT 1 LIMIT 2 ID PLUG ERROR 24VDC OUTPUT 12VDC OUTPUT GND GND LOOP SAFETY OFF SINGLE OPEN ON OFF BATTERY CLOSE DUAL ON ANTI TAILGATE PUSH OPEN PULL OPEN GATE OFF 1 2 3 4 5 6 7 8 9 10 OFF 1 5 6...

Page 35: ...E PORT GATE OPEN GND OPEN ONLY NC OPEN ONLY 10K PHOTO CLS NC OPEN CLS NC GND 12VDC OUT GND GND GND GND GND JOG CLOSE JOG OPEN TAMPER IN TAMPER NO GATE DISABLE KEYPAD CARD GND GND MAX OPEN FIRE DEPT RA...

Page 36: ...ock The gates will not have any play in CLOSED position they are locked in place Single Gate Secondary gate must have a positive stop such as a trim piece on the SECONDARY gate that overlaps primary g...

Page 37: ...R 2 MOTOR 1 ERD OBD PORT BLACK BOX PROGRAMMING SOLAR MODE MOTOR OVER LOAD ERD MOTOR OVER LOAD MIN MAX OFF MAX SENSE MAX SENSE BATTERY BACKUP MODE ERD SENSITIVITY MOTION CONTROL OPEN CLOSING GATE SPEED...

Page 38: ...w for solar mode Control Panel Solar Regulator 24V 10A Morning Star 24V Solar Panel Output 36V max Open Circuit Wire solar panel terminals to solar regulator input Caution polarity matters Solar Panel...

Page 39: ...Flashes 25 change of Inductance Both LED s Flashing CurrentLoop Fault PW R LED Flashing Previous Loop Fault EDI Tel 480 968 6407 DEFLECTO METER SENS RESET POWER DETECT EDI SENS LMA1800 LP OPTIONS 1 2...

Page 40: ...E Total System Current Draw mA Cycles day w 1 rainy day Cycles day w 10 rainy days Cycles day w 1 rainy day Cycles day w 10 rainy days Cycles day w 1 rainy day Cycles day w 10 rainy days 60 W 26 1328...

Page 41: ...2021 10 58 53 INFO SEC_MC Fully Open Posi on Learned Fri 07 11 2021 10 57 40 INFO PRI_CIO Communica on Established Fri 07 11 2021 10 57 38 ENTRAP PRI_MC Photo Cell Deac vated Fri 07 11 2021 10 57 34...

Page 42: ...PEN 1 TIME then if AC power is lost gate will automatically open 1 time If CLOSE TIMER is OFF then gate will not close automatically A close command radio close is required to close gate Loop detector...

Page 43: ...ON OFF switch is ON If so check AC power Battery needs to be replaced if BATTERY TEST fails and REPLACE BATTERY LED is ON Battery not plugged in to BATTERY INPUT port An entrapment event has occurred...

Page 44: ...oop Detector might be defective Replace defective loop detector NOTE RENO loop detector LED s flash as default but function normally ignore the flashing Loop fault condition check if SAFETY loop wires...

Page 45: ...nsor wiring OMRON E3K R10K4 Wiring DSP Arm Controller DSP Arm Controller 45 MAX Arm Ultra Arm V1b CLOSING Direction Photocell Re ector NORMALLY CLOSED NC Wiring to E3K Photocell Pre 2018 WITHOUT Built...

Page 46: ...CLS NC to photocell NO1 Wire GND to photocell C 1 4 Align photocell to reflector 5 Adjust sensitivity DO NOT connect to NC1 3 OPEN ONLY NC OPEN ONLY 10K PHOTO CLS NC OPEN CLS NC GND 12VDC OUT GND CLS...

Page 47: ...r WEL 200R Wireless Edge link Opening Sensing Edge Closing Sensing Edge DSP Arm Controller 47 MAX Arm Ultra Arm V1b 4 Rev 06 16 22 CH1 LLD1 LLD2 LLD3 LLD4 CH2 CH3 CH4 EARTH 10K 10K JP1 JP2 COM OUT PUL...

Page 48: ...behavior double check the edge wiring termination and transmitter batteries CONNECTING RECEIVER TO TRANSMITTER O N 1 2 3 4 MODE OPEN CLOSE WEL 200T Wireless Edge link SW1 LED 3 CH1 LLD1 CH1 LLD1 CH1 s...

Page 49: ...NOTE If photocell does NOT function using VRX power input connect power to VTX input instead emx irb ret OPEN ONLY NC OPEN ONLY 10K PHOTO CLS NC OPEN CLS NC GND 12VDC OUT GND CLS ONLY 10K OPEN CLS 10...

Page 50: ...E L S Photocell Thru Beam CLOSING Direction Single Gate Operator Control Box DSP Arm Controller 50 MAX Arm Ultra Arm V1 2 08 09 22 IMPORTANT Photocells MUST be powered by 12VDC OUT or they will NOT be...

Page 51: ...erator Control Box DSP Arm Controller 49 MAX Super 1300 2300 Arms V1 emx irb mon Photocell Thru Beam CLOSING Direction Dual Gate Operators Control Box To PHOTO CLS NC and 12VDC OUT Input To 12VDC OUTP...

Page 52: ...T LOOP 16 MIN 16 MIN 3 1 14 12 9 7 3 1 14 12 9 7 UL SENSOR 10K UL SENSOR N C MODE A MODE B PROGRAM MOTOR 1 INPUTS MOTOR 2 INPUTS MAXIMUM CONTROLS DSP ARM CONTROLLER MIN AP AGLOCK ELAY JOG EN ON O BATT...

Page 53: ...M L P ARM CONTROL 1 OFF 2 OFF 3 OFF 4 OFF 5 ON 6 ON Both safety edges are 10K resistive Pos Neg NO1 C1 C2 NO2 Can be mounted on Gate s OPENING OR CLOSING position Can be mounted on Gate s OPENING OR C...

Page 54: ...6 7 8 5 Op tim um Sen s Inc rea se Sen s De cre ase Sen s DE FL EC TO ME TE R PO WE R ON No rm al Pow er OF F No Pow er LE D IND ICA TO RS DE TEC T ON De tec t OF F No De tec t 2 Hz Fla sh Del ay Tim...

Page 55: ...ALWAYS verify that power is OFF BEFORE manually releasing gate OWNER of the gate operator is responsible for the KEY availability WARNING WARNING NEVER grasp the arm to move gate ALWAYS grasp gate to...