16
MAX Super 1300/2300 Arms V1
mounting 2300 arm information
Bottom
Middle
Top
Support Bar
Bottom
Installation Note:
Make sure that
the operator is
mounted high
enough off the
ground that it will
NOT come in
contact with
standing or
flowing water.
This will damage
the operator.
Arm MUST be level!
IMPORTANT:
Drive rod MUST NOT be FULLY extended when installed. This will damage the arm.
Rotate fully extended rod back at least two full turns BEFORE installing the arm.
Rotate rod back 2 turns min.
Release the drive rod and fully extend
Gate must be in good working condition before the actuator arm can be installed. Determine what direction the actuator arm
will open the gate: “PULL OPEN” or “PUSH OPEN” Installation (See next page). See the “GATE SAFETY and REQUIREMENTS” in
front of this manual (pages 4-11) for mounting requirements and limitations.
Drive Rod Extension
Temporarily mount arm in desired position determined by next page’s dimensions. Manually swing gate to the OPEN and CLOSE
positions. When satisfied with gate positions, permanently mount brackets making sure that arm is LEVEL.
Temporarily Mount Arm
If brackets are going to be welded to the gate and/or wall, only tack weld the brackets with the arm attached.
Protect the arm
from welding sparks during tack welding.
Remove arm before completely welding around the brackets. Make sure the
brackets are level when tack welding them! The arm will not operate properly if not level.
Welding Brackets to Surfaces
Gate Support Bar
A support bar that spans the entire length of the gate must be installed to keep the pickets from bending. Do not mount the
front bracket directly to gate pickets!
Flex Conduit
The operator wire needs to be in a flexible conduit (not provided).